![Mitsubishi Electric FR-F820-00046 Instruction Manual Download Page 788](http://html.mh-extra.com/html/mitsubishi-electric/fr-f820-00046/fr-f820-00046_instruction-manual_1811886788.webp)
Ethernet communication (FR-F800-E)
Parameters
5 - 616
●
When Pr. 544 = "18 or 28" (compatible with the octuple setting of CC-Link Ver.2)
– Remote I/O (32 points (128 points occupied))
Same as when Pr. 544 = 0 (refer to page 5-613).
– Remote register
Valid when Pr. 128 ="50, 51, 60, or 61".
"n" indicates a value determined by the station number setting.
Description
Refer to
page
Upper 8 bits
Lower 8 bits
RWwn
Monitor code 2
Monitor code 1
RWwn+1
Set frequency (0.01 Hz increments)
RWwn+2
Link parameter
extended setting
Instruction code
RWwn+3
Write data
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
RWwn+8
Faults history No.
H00
RWwn+9
PID set point (0.01% increments)
RWwn+A
PID measured value (0.01% increments)
RWwn+B
PID deviation (0.01% increments)
RWrn+C
H00 (Free)
—
RWrn+D
H00 (Free)
—
RWrn+E
H00 (Free)
—
RWrn+F
H00 (Free)
—
RWwn+10
Link parameter
extended setting
Instruction code
RWwn+11
Write data
RWwn+12
Link parameter
extended setting
Instruction code
RWwn+13
Write data
RWwn+14
Link parameter
extended setting
Instruction code
RWwn+15
Write data
RWwn+16
Link parameter
extended setting
Instruction code
RWwn+17
Write data
RWwn+18
Link parameter
extended setting
Instruction code
RWwn+19
Write data
RWwn+1A
to
RWwn+1F
H00 (Free)
—
Tab. 5-341:
Remote registers (write)
Description
Refer to
page
Upper 8 bits
Lower 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code 2
Reply code 1
RWrn+3
Read data
RWrn+4
Third monitor value
RWrn+5
Fourth monitor value
RWrn+6
Fifth monitor value
RWrn+7
Sixth monitor value
RWrn+8
Faults history No.
Fault data
RWrn+9
Fault record (output frequency)
RWrn+A
Fault record (output current)
RWrn+B
Fault record (output voltage)
RWrn+C
Fault record (energization time)
RWrn+D
H00 (Free)
—
RWrn+E
RWrn+F
RWrn+10
Reply code
RWrn+11
Read data
RWrn+12
Reply code
RWrn+13
Read data
RWrn+14
Reply code
RWrn+15
Read data
RWrn+16
Reply code
RWrn+17
Read data
RWrn+18
Reply code
RWrn+19
Read data
RWrn+1A to
RWrn+1F
H00 (Free)
—
Tab. 5-342:
Remote registers (read)
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......