Perform Basic Operations
60
Table of Display Modes
The following table lists the 5 display modes used to control the inverter functions.
Mode Name
Keypad Display Description
Monitor mode
MON
Displays the inverter’s operation status information. In this
mode, information including the inverter’s frequency
reference, operation frequency, output current, and voltage
may be monitored.
Parameter mode
PAR
Used to configure the functions required to operate the
inverter. These functions are divided into 14 groups based
on purpose and complexity.
User & Macro
mode
U&M
Used to define User groups and Macro groups. These user-
definable groups allow specific functions of the inverter to
be grouped and managed in separate groups.
This mode is not displayed when you navigate through the
modes if no user groups or Macro groups have been
defined.
Trip mode
TRP
Used to monitor the inverter’s fault trip information,
including the previous fault trip history.
When a fault trip occurs during inverter operation, the
operation frequency, output current, and output voltage of
the inverter at the time of the fault may be monitored.
This mode is not displayed if the inverter is not at fault and
fault trip history does not exist.
Config mode
CNF
Used to configure the inverter features that are not directly
related to the operation of the inverter. The settings you
can configure in the Config mode include keypad display
language options, monitor mode environment settings,
communication module display settings, and parameter
duplication and initialization.
Summary of Contents for 6731001500
Page 1: ......
Page 17: ...Preparing the Installation 4 37 90kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500kW 3 Phase ...
Page 34: ...21 Installing the Inverter 400 V 220 500kW ...
Page 50: ...37 Installing the Inverter Inputand OutputControlTerminalBlockWiringDiagram 5 5 90kW ...
Page 66: ...Perform BasicOperations 53 ...
Page 106: ...93 Learning BasicFeatures 0 10V InputVoltageSettingDetails V1 Quantizing ...
Page 107: ...94 Learning BasicFeatures ...
Page 187: ...174 Learning Advanced Features PIDCommandBlock ...
Page 188: ...175 Learning Advanced Features ...
Page 189: ...176 Learning Advanced Features PIDFeedbackBlock ...
Page 190: ...177 Learning Advanced Features PIDOutputBlock ...
Page 191: ...178 Learning Advanced Features PIDOutputModeBlock ...
Page 205: ...192 Learning Advanced Features EPID1Controlblock ...
Page 206: ...193 Learning Advanced Features EPID2Controlblock ...
Page 228: ...215 Learning Advanced Features ...
Page 244: ...231 Learning Advanced Features TheTime Chartfor the Exception Day ...
Page 260: ...247 Learning Advanced Features SpeedSearchOperation SettingDetails ...
Page 405: ...392 RS 485 Communication Features 7 3 9 2 Control Area Parameter Read Write ...
Page 555: ...Table ofFunctions 542 8 16 4 CoolingTower MC4 Group ...
Page 558: ...Tableof Functions 545 8 16 5 Circulation Pump MC5 Group ...
Page 562: ...Tableof Functions 549 8 16 6 Vacuum Pump MC6 Group ...
Page 588: ...575 Troubleshooting ...
Page 608: ...TechnicalSpecification 595 11 3 External Dimensions 0 75 30kW 3 phase 37 90kW 3 phase ...
Page 609: ...TechnicalSpecification 596 110 185kW 3 phase ...
Page 632: ...TechnicalSpecification 619 400 V 37 500 kW Current Derating Rate ...
Page 643: ...630 ...
Page 644: ...631 ...
Page 645: ...632 ...