Table
of Functions
431
Code
Comm.
Address
Name
LCD
Display
Setting Range
Initial Value
Prope
rty*
Ref.
control
Control
1 Always ON
p.254
2
Temp
Control
65
0h1341
Up/Down
operation
frequency
save
U/D Save
Mode
0 No
0: No
O
p.155
1 Yes
66
0h1342
Output
contact
On/Off
control
options
On/Off
Ctrl Src
0 None
0: None
O
p.294
1 V1
3 V2
4 I2
6 Pulse
7
23
V3
8 I3
67
0h1343
Output
contact On
level
On-Ctrl
Level
Output contact
off level-
100.00%
90.00
Δ
p.294
68
0h1344
Output
contact Off
level
Off-Ctrl
Level
-100.00-
outputcontact
on level (%)
10.00
Δ
p.294
70
0h1346
Safe
operation
selection
Run En
Mode
0
Always
Enable
0: Always
Enable
Δ
p.158
1
DI
Dependent
71
24
0h1347
Safe
operation
Run Dis
Stop
0 Free-Run
0: Free-Run
Δ
p.158
1 Q-Stop
23
‘10(V3)~11(I3)’ of ADV-66 are available when Extension IO option is equipped. Refer to
Extension IO option manual for more detailed information.
24
ADV-71–72 are displayed when ADV-70 is set to ‘1 (DI Dependent)’.
Summary of Contents for 6731001500
Page 1: ......
Page 17: ...Preparing the Installation 4 37 90kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500kW 3 Phase ...
Page 34: ...21 Installing the Inverter 400 V 220 500kW ...
Page 50: ...37 Installing the Inverter Inputand OutputControlTerminalBlockWiringDiagram 5 5 90kW ...
Page 66: ...Perform BasicOperations 53 ...
Page 106: ...93 Learning BasicFeatures 0 10V InputVoltageSettingDetails V1 Quantizing ...
Page 107: ...94 Learning BasicFeatures ...
Page 187: ...174 Learning Advanced Features PIDCommandBlock ...
Page 188: ...175 Learning Advanced Features ...
Page 189: ...176 Learning Advanced Features PIDFeedbackBlock ...
Page 190: ...177 Learning Advanced Features PIDOutputBlock ...
Page 191: ...178 Learning Advanced Features PIDOutputModeBlock ...
Page 205: ...192 Learning Advanced Features EPID1Controlblock ...
Page 206: ...193 Learning Advanced Features EPID2Controlblock ...
Page 228: ...215 Learning Advanced Features ...
Page 244: ...231 Learning Advanced Features TheTime Chartfor the Exception Day ...
Page 260: ...247 Learning Advanced Features SpeedSearchOperation SettingDetails ...
Page 405: ...392 RS 485 Communication Features 7 3 9 2 Control Area Parameter Read Write ...
Page 555: ...Table ofFunctions 542 8 16 4 CoolingTower MC4 Group ...
Page 558: ...Tableof Functions 545 8 16 5 Circulation Pump MC5 Group ...
Page 562: ...Tableof Functions 549 8 16 6 Vacuum Pump MC6 Group ...
Page 588: ...575 Troubleshooting ...
Page 608: ...TechnicalSpecification 595 11 3 External Dimensions 0 75 30kW 3 phase 37 90kW 3 phase ...
Page 609: ...TechnicalSpecification 596 110 185kW 3 phase ...
Page 632: ...TechnicalSpecification 619 400 V 37 500 kW Current Derating Rate ...
Page 643: ...630 ...
Page 644: ...631 ...
Page 645: ...632 ...