Learning Advanced Features
Advanced Tasks
Description
Ref.
Auto restart
operation
Auto restart configuration is used to automatically restart the
inverter when a trip condition is released, after the inverter stops
operating due to activation of protective devices (fault trips).
p.248
Second motor
operation
Used to switch equipment operation by connecting two motors to
one inverter. Configure and operate the second motor using the
terminal input defined for the second motor operation.
p.251
Commercial power
source switch
operation
Used to switch the power source to the motor from the inverter
output to a commercial power source, or vice versa.
p.253
Cooling fan control
Used to control the cooling fan of the inverter.
p.254
Multi-function
output On/Off
control
Set standard values and turn On/Off the output relays or multi-
function output terminals according to the analog input value.
p.294
Regeneration
prevention for press
operation.
Used during a press operation to avoid motor regeneration, by
increasing the motor operation speed.
p.253
Damper operation
Controls the fan motor optimally when a damper is used in the
system.
p.194
Lubrication
operation
Supplies lubricant to the machinery before starting the inverter and
the mechanical system connected to it.
p.196
Flow compensation
Compensates for pressure loss in a system with long pipelines.
p.194
Energy savings
display
Displays the amount of energy saved by the use of the inverter,
compared to when a commercial power source is used without an
inverter.
p.198
Pump clean
operation
Cleans the pumps by removing the scales or deposits that are
attached to the impeller.
p.200
Inclination setting
for operation and
stop
Sets the initial operating conditions for a pump by adjusting the
acceleration and deceleration times.
p.204
Valve deceleration
time setting
Prevents possible pump damage that may be caused by abrupt
deceleration.
p.206
Load tuning
Creates load-specific curves for light load operations and the pump
clean operation.
p.207
Level detection
Detects and displays the level set by the user.
p.209
Pipe breakage
detection
Detects breakages in the pipeline during a PID operation.
p.213
Motor preheating
Prevents motors and pumps from freezing when they are not
operated.
p.216
Scheduled
operation
Uses the built-in real-time clock (RTC) to operate the inverter
according to the desired time schedule.
p.222
Summary of Contents for 6731001500
Page 1: ......
Page 17: ...Preparing the Installation 4 37 90kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500kW 3 Phase ...
Page 34: ...21 Installing the Inverter 400 V 220 500kW ...
Page 50: ...37 Installing the Inverter Inputand OutputControlTerminalBlockWiringDiagram 5 5 90kW ...
Page 66: ...Perform BasicOperations 53 ...
Page 106: ...93 Learning BasicFeatures 0 10V InputVoltageSettingDetails V1 Quantizing ...
Page 107: ...94 Learning BasicFeatures ...
Page 187: ...174 Learning Advanced Features PIDCommandBlock ...
Page 188: ...175 Learning Advanced Features ...
Page 189: ...176 Learning Advanced Features PIDFeedbackBlock ...
Page 190: ...177 Learning Advanced Features PIDOutputBlock ...
Page 191: ...178 Learning Advanced Features PIDOutputModeBlock ...
Page 205: ...192 Learning Advanced Features EPID1Controlblock ...
Page 206: ...193 Learning Advanced Features EPID2Controlblock ...
Page 228: ...215 Learning Advanced Features ...
Page 244: ...231 Learning Advanced Features TheTime Chartfor the Exception Day ...
Page 260: ...247 Learning Advanced Features SpeedSearchOperation SettingDetails ...
Page 405: ...392 RS 485 Communication Features 7 3 9 2 Control Area Parameter Read Write ...
Page 555: ...Table ofFunctions 542 8 16 4 CoolingTower MC4 Group ...
Page 558: ...Tableof Functions 545 8 16 5 Circulation Pump MC5 Group ...
Page 562: ...Tableof Functions 549 8 16 6 Vacuum Pump MC6 Group ...
Page 588: ...575 Troubleshooting ...
Page 608: ...TechnicalSpecification 595 11 3 External Dimensions 0 75 30kW 3 phase 37 90kW 3 phase ...
Page 609: ...TechnicalSpecification 596 110 185kW 3 phase ...
Page 632: ...TechnicalSpecification 619 400 V 37 500 kW Current Derating Rate ...
Page 643: ...630 ...
Page 644: ...631 ...
Page 645: ...632 ...