221
Learning Advanced Features
Motor Capacity
(kW)
Rated
Current
(A)
No-load
Current
(A)
Rated Slip
Frequency
(Hz)
Stator
Resistance
(
Ω
Ω
Ω
Ω
)
Leakage
Inductance
(mH)
400 V
110
203.5
48.8
1.00
0.0326
0.585
132
242.3
58.1
1.00
0.0272
0.488
160
290.5
69.7
1.00
0.0224
0.403
185
335.0
77.0
1.00
0.0210
0.380
220
405.0
93.1
1.00
0.1630
2.930
250
467.8
104.9
1.00
0.1455
2.615
315
604.0
132.8
1.00
0.1140
2.040
355
687.8
146.4
1.00
0.1020
1.820
400
782.0
161.2
1.00
0.0906
1.616
500
985.3
206.2
1.00
0.0700
1.330
Auto Tuning Parameter Setting Details
Code
Description
DRV-14 Motor Capacity
Sets the motor capacity to be used. The maximum motor capacity is
limited by the inverter capacity and the keypad only displays the
inverter capacity.
BAS-20 Auto Tuning
Select an auto tuning type and run it. Select one of the options and
then press the [ENT] key to run the auto tuning.
Setting
Function
0
None
Auto tuning function is disabled. Also, if you
select one of the auto tuning options and run it,
the parameter value will revert back to ‘0’ when
the auto tuning is complete.
1
All
(rotating
type)
Measures all motor parameters while the motor
is rotating, including stator resistance (Rs), no-
load current (Noload Curr), rotor time constant
(Tr), etc. Since the motor is rotating while the
parameters are being measured, if the load is
connected to the motor spindle, the parameters
may not be measured accurately. For accurate
measurements, remove the load attached to the
motor spindle.
Summary of Contents for 6731001500
Page 1: ......
Page 17: ...Preparing the Installation 4 37 90kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500kW 3 Phase ...
Page 34: ...21 Installing the Inverter 400 V 220 500kW ...
Page 50: ...37 Installing the Inverter Inputand OutputControlTerminalBlockWiringDiagram 5 5 90kW ...
Page 66: ...Perform BasicOperations 53 ...
Page 106: ...93 Learning BasicFeatures 0 10V InputVoltageSettingDetails V1 Quantizing ...
Page 107: ...94 Learning BasicFeatures ...
Page 187: ...174 Learning Advanced Features PIDCommandBlock ...
Page 188: ...175 Learning Advanced Features ...
Page 189: ...176 Learning Advanced Features PIDFeedbackBlock ...
Page 190: ...177 Learning Advanced Features PIDOutputBlock ...
Page 191: ...178 Learning Advanced Features PIDOutputModeBlock ...
Page 205: ...192 Learning Advanced Features EPID1Controlblock ...
Page 206: ...193 Learning Advanced Features EPID2Controlblock ...
Page 228: ...215 Learning Advanced Features ...
Page 244: ...231 Learning Advanced Features TheTime Chartfor the Exception Day ...
Page 260: ...247 Learning Advanced Features SpeedSearchOperation SettingDetails ...
Page 405: ...392 RS 485 Communication Features 7 3 9 2 Control Area Parameter Read Write ...
Page 555: ...Table ofFunctions 542 8 16 4 CoolingTower MC4 Group ...
Page 558: ...Tableof Functions 545 8 16 5 Circulation Pump MC5 Group ...
Page 562: ...Tableof Functions 549 8 16 6 Vacuum Pump MC6 Group ...
Page 588: ...575 Troubleshooting ...
Page 608: ...TechnicalSpecification 595 11 3 External Dimensions 0 75 30kW 3 phase 37 90kW 3 phase ...
Page 609: ...TechnicalSpecification 596 110 185kW 3 phase ...
Page 632: ...TechnicalSpecification 619 400 V 37 500 kW Current Derating Rate ...
Page 643: ...630 ...
Page 644: ...631 ...
Page 645: ...632 ...