Troubleshooting
564
General Fault Trips
LCD Display
Type
Description
Damper Err
Latch
Triggered when the damper open signal or run command signal is
longer than the value set at AP2-45 (Damper Check T) during a fan
operation.
MMC Interlock
Latch
Triggered when AP1-55 is set to ‘2’ and all auxiliary motors are
interlocked during an MMC operation.
CleanRPTErr
Latch
Triggered when the pump clean operation is operated frequently.
The conditions may be modified with theAP2-36–AP2-37 settings.
Pipe Broken
Latch
Triggered when a pipe is broken during the pump operation. Set
PRT-60.
Level Detect
Latch
Triggered when the inverter output current or power is lower or
higher than the values set by the user. Set the values at PRT-71–
PRT-77.
Broken Belt
Latch
Triggered when PRT-91 is set to Free Run
Option Protection
LCD Display
Type
Description
Lost Command
Level
Displayed when a frequency or operation command error is
detected during inverter operation by controllers other than the
keypad (e.g., using a terminal block and a communication mode).
Activate by setting PRT-12 to any value other than ‘0’.
IO Board Trip
Latch
Displayed when the I/O board or external communication card is
not connected to the inverter or there is a bad connection.
ParaWrite Trip
Latch
Displayed when communication fails during parameter writing.
Occurs due to a control cable fault or a bad connection.
Option Trip-1
Latch
Displayed when a communication error is detected between the
inverter and the communication board. Occurs when the
communication option card is installed.
Summary of Contents for 6731001500
Page 1: ......
Page 17: ...Preparing the Installation 4 37 90kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500kW 3 Phase ...
Page 34: ...21 Installing the Inverter 400 V 220 500kW ...
Page 50: ...37 Installing the Inverter Inputand OutputControlTerminalBlockWiringDiagram 5 5 90kW ...
Page 66: ...Perform BasicOperations 53 ...
Page 106: ...93 Learning BasicFeatures 0 10V InputVoltageSettingDetails V1 Quantizing ...
Page 107: ...94 Learning BasicFeatures ...
Page 187: ...174 Learning Advanced Features PIDCommandBlock ...
Page 188: ...175 Learning Advanced Features ...
Page 189: ...176 Learning Advanced Features PIDFeedbackBlock ...
Page 190: ...177 Learning Advanced Features PIDOutputBlock ...
Page 191: ...178 Learning Advanced Features PIDOutputModeBlock ...
Page 205: ...192 Learning Advanced Features EPID1Controlblock ...
Page 206: ...193 Learning Advanced Features EPID2Controlblock ...
Page 228: ...215 Learning Advanced Features ...
Page 244: ...231 Learning Advanced Features TheTime Chartfor the Exception Day ...
Page 260: ...247 Learning Advanced Features SpeedSearchOperation SettingDetails ...
Page 405: ...392 RS 485 Communication Features 7 3 9 2 Control Area Parameter Read Write ...
Page 555: ...Table ofFunctions 542 8 16 4 CoolingTower MC4 Group ...
Page 558: ...Tableof Functions 545 8 16 5 Circulation Pump MC5 Group ...
Page 562: ...Tableof Functions 549 8 16 6 Vacuum Pump MC6 Group ...
Page 588: ...575 Troubleshooting ...
Page 608: ...TechnicalSpecification 595 11 3 External Dimensions 0 75 30kW 3 phase 37 90kW 3 phase ...
Page 609: ...TechnicalSpecification 596 110 185kW 3 phase ...
Page 632: ...TechnicalSpecification 619 400 V 37 500 kW Current Derating Rate ...
Page 643: ...630 ...
Page 644: ...631 ...
Page 645: ...632 ...