English
Burner malfunctions with oil-fired devices
1
Exhaust gas thermostat release button
2
Unlocking button for automatic oil firing unit
3
Burner controller electrical box
Burner malfunctions with gas-fired devices
Malfunctions on the gas burner may only be repaired by
authorised specialist personnel of the burner manufac-
turer.
Coin slot malfunctions
Malfunction
Possible cause
Rectification
By whom
Oil firing malfunction (au-
tomatic oil firing unit) in
the electrical box of the
burner controller was trig-
gered)
No ignition spark present (visible
through the sight glass in the burner
cover)
Check electrode setting, ignition transformer and ignition cable. Clean electrodes,
replace defective parts. Then press the release button of the automatic oil firing
unit.
Customer Service
Sight glass for flame monitoring is dirty Clean the sight glass for flame monitoring (see section "Maintenance work"). Then
press the release button of the automatic oil firing unit.
Operator
Light sensor for flame monitoring is not
in holder or defective
Reattach or replace the light sensor. Then press the release button of the automat-
ic oil firing unit.
Operator, Customer
Service
Fuel oil level too low
Refill the fuel tank. Then press the release button of the automatic oil firing unit. Operator
No flame due to a shortage of fuel
Clean the fuel filter on the fuel pump. Then press the release button of the auto-
matic oil firing unit.
Operator
Clean the fuel nozzle and replace if necessary. Then press the release button of
the automatic oil firing unit.
Operator
Check the fuel solenoid valve, the fuel pump and the coupling.
Customer Service
No flame due to a shortage of air
Check the collar on the blower for damage and tight fit of the straps. Then press
the release button of the automatic oil firing unit.
Operator
The blower is defective, replace it. Then press the release button of the automatic
oil firing unit.
Customer Service
Strong smoke develop-
ment during start-up and
operation
Ignition electrode lies in the fuel jet
Check and correct the electrode setting.
Operator, Customer
Service
Fuel pressure incorrectly set (see sec-
tion "Technical data")
Check the fuel pressure, set it again if necessary.
Customer Service
Heating coil heavily sooted
Dismantle the boiler and clean the heating coil.
Customer Service
Exhaust gas thermostat
(S5) was triggered
Washing water circuit is calcified
Check the water treatment, descale the hot water circuit. Then press the exhaust
gas thermostat release button.
Customer Service
Heating coil heavily sooted
Dismantle the boiler and clean the heating coil. Then press the exhaust gas ther-
mostat release button.
Customer Service
Burner is incorrectly set
Correct the burner setting. Then press the exhaust gas thermostat release button. Customer Service
Malfunction
Possible cause
Rectification
By whom
All coin acceptors reject
all coins.
Main switch switched off.
Turn the main switch to "1".
Operator
Time or operating times incorrectly set.
Night-time operation lock active.
Check the settings at the controller.
Operator
Water shortage
Check the water supply.
Operator
The motor circuit breaker of the high-
pressure pump has triggered.
Reset the motor circuit breaker. Search for the cause if this occurs repeatedly.
Operator
A single coin acceptor re-
jects all coins.
Coin acceptor dirty.
Clean the coin slot (see section "Maintenance work").
Operator
Overcurrent at the high-pressure
pump.
Acknowledge the error at the controller.
Operator
Summary of Contents for SB MB
Page 39: ...Deutsch 39 Ma blatt Variante CAB SB MB Standard SB MB Comfort...
Page 40: ...40 Deutsch Ma blatt Variante SKID SB MB Standard SB MB Comfort...
Page 41: ...Deutsch 41 Ma blatt Variante SKID mit Anbausatz WSO...
Page 80: ...80 English Dimension sheet variant CAB SB MB standard SB MB comfort...
Page 81: ...English 81 Dimension sheet variant SKID SB MB standard SB MB comfort...
Page 82: ...82 English Dimension sheet variant SKID with attachment kit WSO...
Page 123: ...Fran ais 123 Fiche de dimensions variante CAB SB MB Standard SB MB Comfort...
Page 124: ...124 Fran ais Fiche de dimensions variante SKID SB MB Standard SB MB Comfort...
Page 125: ...Fran ais 125 Fiche de dimensions variante SKID avec kit de montage WSO...
Page 165: ...Italiano 165 Scheda dimensionale variante CAB SB MB Standard SB MB Comfort...
Page 166: ...166 Italiano Scheda dimensionale variante SKID SB MB Standard SB MB Comfort...
Page 167: ...Italiano 167 Scheda dimensionale variante SKID con kit di fissaggio WSO...
Page 206: ...206 Nederlands Maatblad variant CAB SB MB standaard SB MB comfort...
Page 207: ...Nederlands 207 Maatblad variant SKID SB MB standaard SB MB comfort...
Page 208: ...208 Nederlands Maatblad variant SKID met aanbouwset WSO...
Page 248: ...248 Espa ol Hoja de medidas variante CAB SB MB Standard SB MB Comfort...
Page 249: ...Espa ol 249 Hoja de medidas variante SKID SB MB Standard SB MB Comfort...
Page 250: ...250 Espa ol Hoja de medidas variante SKID con juego de montaje WSO...
Page 289: ...Svenska 289 M ttblad variant CAB SB MB Standard SB MB Comfort...
Page 290: ...290 Svenska M ttblad variant SKID SB MB Standard SB MB Comfort...
Page 291: ...Svenska 291 M ttblad variant SKID med p byggnadssats WSO...
Page 330: ...330 Suomi Mittalehti versio CAB SB MB Standard SB MB Comfort...
Page 331: ...Suomi 331 Mittalehti versio SKID SB MB Standard SB MB Comfort...
Page 332: ...332 Suomi Mittalehti versio SKID liit nt sarjalla WSO...
Page 337: ...337 2 3 4 2 A 3 3 Powerschaum STOP 1 SB MB Comfort 2 SB MB Comfort 3 SB MB Standard 4 5 6...
Page 353: ...353 1 2 2 3 4 5 6 1 7 8 9 10 11 12 13 2 3 4...
Page 354: ...354 1 2 2 3 4 5 6 1 7 8 9 10 11 3 2 3 4 1 2 3 4 5 6 7 8 9 10 11...
Page 355: ...355 SB MB Standard SB MB Comfort RO RO RO RO RO 4 60 C 0 OFF 1 2 K RCHER K RCHER...
Page 358: ...358 SB MB 6 419 070 0 25 C 0 07 0 15 MPa 0 7 1 5 bar 0 5 l min 0 0 5 l min 2 WZ 30 mm 5 C ABS...
Page 360: ...360 1000 WSO Power Power WSO RO 5...
Page 364: ...364 1 2 3 10 C F0144 S5...
Page 365: ...365 1...
Page 366: ...366 1 1 2 3 0 6 mm 4 1 3 mm 5 6 7 8 0 25 MPa 2 5 bar WAT S 202 WAT S 202 2...
Page 367: ...367 0 3 MPa 3 bar RO RO RO RO RO...
Page 373: ...373 CAB SB MB Standard SB MB Comfort...
Page 374: ...374 SKID SB MB Standard SB MB Comfort...
Page 375: ...375 SKID WSO...
Page 376: ...376...
Page 381: ...381 1 2 3 4 5 6 7 8 2 9 1 10 11 12 13 14 1 0 4 0 5 4 5 1 2 3 4 1 DP 1 2 DP 2 3 DP 3 4 DP 4 1 0...
Page 384: ...384 1 2 1 2 3 4 5 6 7 8 9 10 1 1 2 1 2 3 4 5 6 7 8 9 10 Home 1 2 3 4 5 6 Home 7 1 8 2 2 1 2...
Page 391: ...391 1 1 1 1 1 1 2 3 2 3 4 1 0 OFF 1 1 ON 2 3 1 2 1 2 3 4 5 6 7 8 9...
Page 394: ...394 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 1 2 48 3 4 24 48 5 6 7 8 1 80 100 2 3...
Page 395: ...395 B C 1 2 3 4 5 6 7 8 9 10 1 11 1 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...
Page 397: ...397 1 2 2 3 4 5 6 1 7 8 9 10 11 12 13 2 3 4...
Page 398: ...398 1 2 2 3 4 5 6 1 7 8 9 10 11 3 2 3 4 1 2 3 4 5 6 7 8 9 10 11...
Page 399: ...399 SB MB Standard SB MB Comfort 4 60 0 OFF 1 2 K RCHER K RCHER...
Page 401: ...401 1 2 3 WSO 1 6 1 1 6 2 1 2 1 2 3 1 2 3 4 5 6 1 IP 2 3 4 1 1 2 3 4 1 2 3 4...
Page 402: ...402 SB MB 6 419 070 0 25 C 0 07 0 15 0 7 1 5 0 5 0 0 5 2 30 5 C...
Page 404: ...404 200 9 10 90 100 0 5 5 25 6 288 055 0 6 288 072 6 288 116 1000 WSO WSO...
Page 408: ...408 10 C F0144...
Page 409: ...409 1 2 3 S5 1...
Page 410: ...410 1 1 3 0 6 4 1 3 5 6 7 8 0 25 2 5 WAT S 202 WAT S 202 2...
Page 411: ...411 0 3 3...
Page 417: ...417 CAB SB MB Standard SB MB Comfort...
Page 418: ...418 SKID SB MB Standard SB MB Comfort...
Page 419: ...419 SKID WSO...
Page 420: ...420...
Page 422: ......
Page 423: ......