Chapter 3 Specifications for each unit
3.1 SEL Unit, Terminal Unit
3-12
ME0392-4C
(6) Teaching connector
It is a connector to be connected to the PC software or teaching pendant.
Model
HDR-EC26LFDT1-SLD+
Manufacturer
HONDA TSUSHIN KOGYO CO.,LTD
Rated voltage
AC125Vrms
Rated current
0.5A
Voltage Endurance
AC350Vrms
Contact Resistance
70mΩ
or less
Pin
No.
Signal
name
Description
Pin
No.
Signal
name
Description
1
GND
Signal Grounding
14
CTS
Connected to RTS
externally.
Connector connection
detection input.
2
EMGS
Stop status output
15
TXD
Transmit data
3
VCC
6.5V power input connector 16
RXD
Receive data
4
DTR
Terminal ready (Connected
to DSR inside)
17
DSR
Equipment ready
(Connected to DTR inside)
5
Stop contact output 2+
18
NC
Unconnected
6
STOPS2- Stop contact output 2-
19
NC
Unconnected
7
NC
Unconnected
20
NC
Unconnected
(RSVTBX1)
8
RSVVCC
24V power input connector
21
NC
Unconnected
(RSVTBX2)
9
STOPS1- Stop contact output 1-
22
ENBS2+
Enable contact output 2 +
10
NC
Unconnected
23
ENBS1
-
Enable contact output 1 -
11
NC
Unconnected
24
ENBS1+
Enable contact output 1 +
12
Stop contact output 1+
25
ENBS2
-
Enable contact output 2 -
13
RTS
Connected to CTS
externally
26
GND
Signal Grounding
* If this connector is not connected, it should get in condition of STOP being input and in disable
status. It is necessary that the dummy plug: DP-4S is connected when operation of an actuator
is to be performed with the PC cable and the teaching pendant not connected.
3.1 SEL Unit, Terminal Unit
ME0392-4C
3-13
(7) Ethernet connector
It is a connector for Ethernet communication.
Connector type
8P8C
modular connector
Model
TM11R-5M2-88-LP (02)
Manufacturer
Hirose Electric
Pin No.
Signal name
Description
1
TX+
Transmit
+
2
TX-
Transmit -
3
RX+
Receive
+
4
-
5
-
6
RX-
Receive -
7
-
8
-
LED display specifications
LED name
Color
Status
Content
SPEED
Orange
Light ON
100Mbps connection
LINK
Green
Blinking
Link not Established
Light ON
Link Detected
Cable specifications
Item
Specification
Specifications
Category 5 or more
Connector
General Specifications
Durability
Repeated Insertion Life
200
times
LED: SPEED
1
Ethernet
8
LED: LINK
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......