Chapter 6 Field Network, PIO, SIO
6.2
Functional Specifications
6-40
ME0392-4C
[6] PROFIBUS-DP connection type
Example of Use (1)
The relation between the RSEL I/O port numbers and the PLC addresses when it is automatic
assignment, input 48 points and output 32 points is as shown below. The RSEL I/O port start
numbers should be from No. 0 for input and from No. 300 for output, and the assignment on
the PLC side should be made in order from the top address (in 1 byte unit).
RSEL side input port No.
PLC side address (OUT)
RSEL side output port No.
PLC side address (IN)
0 to 15
Top address
300 to 315
Top address
16 to 31
Top 2
316 to 331
Top 2
32 to 48
Top 4
Not available
Top 4
Example of Use (2)
The relation between the RSEL I/O port numbers and the PLC addresses when it is fixed
assignment, input 256 points and output 256 points is as shown below. The RSEL I/O port start
numbers should be from No. 128 for input and from No. 428 for output, and the assignment on
the PLC side should be made in order from the top address (in 1 byte unit).
RSEL side input port No.
PLC side address (OUT)
RSEL side output port No.
PLC side address (IN)
128 to 143
Top address
428 to 443
Top address
144 to 159
Top 2
444 to 459
Top 2
160 to 175
Top 4
460 to 475
Top 4
176 to 191
Top 6
476 to 491
Top 6
192 to 207
Top 8
492 to 507
Top 8
208 to 223
Top 10
508 to 523
Top 10
224 to 239
Top 12
524 to 539
Top 12
240 to 255
Top 14
540 to 555
Top 14
256 to 271
Top 16
556 to 571
Top 16
272 to 287
Top 18
572 to 587
Top 18
288 to 295
1000 to 1007
Top 20
588 to 595
4000 to 4007
Top 20
1008 to 1023
Top 22
4008 to 4023
Top 22
1024 to 1039
Top 24
4024 to 4039
Top 24
1040 to 1055
Top 26
4040 to 4055
Top 26
1056 to 1071
Top 28
4056 to 4071
Top 28
1072 to 1087
Top 30
4072 to 4087
Top 30
6.2
Functional Specifications
ME0392-4C
6-41
Example of Use (3)
The relation between the RSEL I/O port numbers and the PLC addresses when it is automatic
assignment, input 1,024 points and output 1,024 points is as shown below. The RSEL I/O port
start numbers should be from No. 0 for input and from No. 300 for output, and the assignment
on the PLC side should be made in order from the top address (in 1 byte unit).
RSEL side input port No.
PLC side address (OUT)
RSEL side output port No.
PLC side address (IN)
0 to 15
Top
address
300 to 315
Top
address
16 to 31
Top
address
+2
316 to 331
Top
address
+2
32 to 47
Top
address
+4
332 to 347
Top
address
+4
48 to 63
Top
address
+6
348 to 363
Top
address
+6
64 to 79
Top
address
+8
364 to 379
Top
address
+8
80 to 95
Top
address
+10
380 to 395
Top
address
+10
96 to 111
Top
address
+12
396 to 411
Top
address
+12
112 to 127
Top
address
+14
412 to 427
Top
address
+14
128 to 143
Top
address
+16
428 to 443
Top
address
+16
144 to 159
Top
address
+18
444 to 459
Top
address
+18
160 to 175
Top
address
+20
460 to 475
Top
address
+20
176 to 191
Top
address
+22
476 to 491
Top
address
+22
192 to 207
Top
address
+24
492 to 507
Top
address
+24
208 to 223
Top
address
+26
508 to 523
Top
address
+26
224 to 239
Top
address
+28
524 to 539
Top
address
+28
240 to 255
Top
address
+30
540 to 555
Top
address
+30
256 to 271
Top
address
+32
556 to 571
Top
address
+32
272 to 287
Top
address
+34
572 to 587
Top
address
+34
288 to 295
1000 to 1007
Top
address
+36
588 to 595
4000 to 4007
Top
address
+36
1008 to 1023
Top
address
+38
4008 to 4023
Top
address
+38
1024 to 1039
Top
address
+40
4024 to 4039
Top
address
+40
1040 to 1055
Top
address
+42
4040 to 4055
Top
address
+42
1056 to 1071
Top
address
+44
4056 to 4071
Top
address
+44
1072 to 1087
Top
address
+46
4072 to 4087
Top
address
+46
1088 to 1103
Top
address
+48
4088 to 4103
Top
address
+48
1104 to 1119
Top
address
+50
4104 to 4119
Top
address
+50
1120 to 1135
Top
address
+52
4120 to 4135
Top
address
+52
1136 to 1151
Top
address
+54
4136 to 4151
Top
address
+54
1152 to 1167
Top
address
+56
4152 to 4167
Top
address
+56
1168 to 1183
Top
address
+58
4168 to 4183
Top
address
+58
1184 to 1199
Top
address
+60
4184 to 4199
Top
address
+60
1200 to 1215
Top
address
+62
4200 to 4215
Top
address
+62
1216 to 1231
Top
address
+64
4216 to 4231
Top
address
+64
1232 to 1247
Top
address
+66
4232 to 4247
Top
address
+66
1248 to 1263
Top
address
+68
4248 to 4263
Top
address
+68
1264 to 1279
Top
address
+70
4264 to 4279
Top
address
+70
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......