Chapter 10 Parameter
10.2 Parameter List (SEL Unit)
1. I/O parameter
10-18
ME0392-4C
No.
Parameter name
Setting at
Delivery Input range Unit
Remarks
225 I/O controller
Depends on
Controller
Construction
Reference only
0H to
FFFFFFFFH
Bits 0 to 7: Type of Network I/F Module Control 1
(0H: Not mounted,
1H: CC-Link,
2H: DeviceNet,
3H: PROFIBUS-DP,
4 to 5H: Reserved by the system,
6H: EtherCAT,
7H: EtherNet/IP,
8H: Reserved by the system,
9H: PIO,
AH: PROFINET IO,
B to CH: Reserved by the system,
DH: CC-Link IE)
Bits 8 to 31: Reserved by the system
226
I/O1 Fieldbus Node Address
Depends on
Controller
Construction
0 to
99,999,999
Settable Range
•
At CC-Link: 1 to 64
•
At DeviceNet: 0 to 63
•
At PROFIBUS-DP: 0 to 125
•
At EtherCAT: 0 to 65,535
•
At CC-Link IE: 1 to 120
* Setting establishment not necessary for
EtherNet/IP and PROFINET IO
227
I/O1 fieldbus communication
speed
Depends on
Controller
Construction
0 to 9
•
At CC-Link:
(0:156kbps, 1:625kbps, 2:2.5Mbps, 3:5Mbps,
4:10Mbps)
•
At DeviceNet:
(0:125kbps, 1:250kbps, 2:500kbps)
•
At EtherNet/IP:
(0: Auto negotiation
1:10Mbps (Half-Duplex),
2:10Mbps (Full-Duplex),
3:100Mbps (Half-Duplex),
4:100Mbps (Full-Duplex))
* Setting establishment not necessary for
PROFIBUS-DP, EtherCAT, PROFINET IO and
CC-Link IE
228 I/O1 Fieldbus Network Number
Depends on
Controller
Construction
0 to
99,999,999
•
At CC-Link IE: 1 to 239
* Setting not necessary when other than CC-Link IE
229
to
230
(For expansion)
0
231
to
232
Reserved by the system
0
0 to 256
233
Reserved by the system
-1
-1 to 3,999
234
Reserved by the system
-1
-1 to 6,999
235
Reserved by the system
1
0 to 5
236
Reserved by the system
0H
Reference only
0H to
FFFFFFFFH
237
Reserved by the system
0
0 to
99,999,999
238
Reserved by the system
0
0 to 9
239
Reserved by the system
0
0 to
99,999,999
240
to
282
(For expansion)
0
283 Port number assigned to input
function selection 000
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 30, “Input function
selection 000.”
* If a negative value is set, the function will be
assigned to input port No. 0.
284 Port number assigned to input
function selection 001
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 31, “Input function
selection 001.”
* If a negative value is set, the function will be
assigned to input port No. 1.
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......