Chapter 10 Parameter
10.2 Parameter List (SEL Unit)
1. I/O parameter
10-16
ME0392-4C
No.
Parameter name
Setting at
Delivery Input range Unit
Remarks
177 EtherNet I/F
Subnet mask (MH)
255
0 to 255
178 EtherNet I/F
Subnet mask (ML)
255
0 to 255
179 EtherNet I/F
Subnet mask (L)
0
0 to 255
180 EtherNet I/F
Default gateway (H)
0
0 to 255
181 EtherNet I/F
Default gateway (MH)
0
0 to 255
182 EtherNet I/F
Default gateway (ML)
0
0 to 255
183 EtherNet I/F
Default gateway (L)
0
0 to 255
184
Number of CC-Link IE Remote
Registration (Input) Words
(RWw)
Depends on
Controller
Construction
0 to 64
Number of the remote registration words (Inputs in
view from the slave station)
185
Number of CC-Link IE Remote
Registration (Output) Words
(RWr)
Depends on
Controller
Construction
0 to 64
Number of the remote registration words (Outputs in
view from the slave station)
186 Option Unit Connected
0
0 to 8
Unit The number of ports should be number of connected
units x 16 for each input and output.
187 Option Unit
fix-allocated input port start No.
-1
-1 to 3,999
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set)
188
Option Unit
fix-allocated output port start
No.
-1
-1 to 6,999
300 + (Multiple of 8) (300 to 599)
4,000 + (Multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set)
189 PIO Unit / PIO/SIO Unit Error
Monitor
1
0 to 5
0: Not monitored
1: Monitored
2: Monitored (24V I/O power supply related errors
not monitored)
3: Monitored (only 24V I/O power supply related
errors monitored)
4: Monitored (24V I/O power supply related errors
output as message level)
* Some exceptions apply.
190 Option Unit Attribute 1
C800200H
0H to
FFFFFFFFH
Bits 0 to 3: Option unit output port data select in TF
connection error (0: Clear, 1: Hold)
Bits 4 to 7: Option unit input port data select in TF
connection error (0: Clear, 1: Hold)
Bits 8 to 15: TF communication link error check timer
value (10 ms)
Bits 16 to 19: For future extension use
Bits 20 to 31: Link timeout value in communication
initialization (100 ms)
191 EC connection unit JOG switch
0
0 to 1
0: Enable
1: Disable
(Main application part V1.09 or later)
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......