Chapter 3 Specifications for each unit
3.5 SCON Extension Unit, PIO/SIO/SCON Extension Unit, PIO Unit
3-84
ME0392-4C
The SCON extension unit and the SCON-CB controller are connected with a dedicated cable
(model: CB-RE-
CTL□□□). When connecting two or more SCON
-CB controllers, connect the
SCON-CB units together with a dedicated cable. Up to 16 axes can be controlled by combining
with a driver unit.
* In RSEL System, it is available to connect only either the SCON extension units or
PIO/SIO/SCON extension units.
[PIO/SIO/SCON Extension Unit]
PIO/SIO/SCON extension unit is equipped with a connector to link SCON-CB controller as well
as SCON extension unit does.
It is also equipped with the parallel I/O connector with 16 points of input and 16 points of output
and RS-485 serial communication connector.
PIO/SIO/SCON extension units are also available to use by allocating on the right of the SEL unit.
[PIO unit
】
PIO unit is equipped with the parallel I/O connector with 16 points of input and 16 points of output.
Expansion is available up to eight at the maximum (144 points of input and 144 points of output)
including PIO/SIO/SCON extension units.
RSEL system
SCON
Extension Unit or
PIO/SIO/SCON
Extension Unit
(*)
Communication
connector for RCON/RSEL
connection
SCON-CB controller
Connection cable CB-RE-
CTL□□□
Actuator
Cable for each actuator
Refer to SCON-CB
instruction manual
Terminal
connector
RCON-EXT-TR
Top :
OUT
Bottom :
IN
3.5 SCON Extension Unit, PIO/SIO/SCON Extension Unit, PIO Unit
ME0392-4C
3-85
Parameter Setting When PIO/SIO/SCON Extension Unit and PIO Unit Used
The setting in I/O Parameter No. 186 “Number of Connected Option Units” is 0 at the delivery
from our production plant in RSEL System
When PIO input and output are to be used with PIO/SIO/SCON extension units or PIO units
connected, set the total number of PIO/SIO/SCON extension units and PIO units connected in
the parameter.
[Number of Connected Option Units (I/O Parameter No. 186)]
No.
Name
Unit
Input range
Default initial value
setting
186 Number of Connected Option Units
-
0 ~ 8
0
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......