Chapter 6 Field Network, PIO, SIO
6.3 Parameter Configuration
6-92
ME0392-4C
[7] PROFINET IO only
It is the setting when PROFINET IO is to be used for 16 points of each input and output from
the top of the input and output ports (No. 0 ~, No. 300 ~).
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
1
I/O port assignment type
1
1
0: Fixed assignment
1: Automatic assignment
14
Number of Ports Used for
I/O1 Fieldbus Remote Input
0
16
Multiple of 8
15
Number of Ports Used for
I/O1 Fieldbus Remote Output
0
16
Multiple of 8
16
I/O1 fix-allocated input port
start No.
-1
-1
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set.)
17
I/O1 fix-allocated output port
start No.
-1
-1
300 + (multiple of 8) (300 to 599)
4,000 + (multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set.)
18
I/O1 error monitor
1
1
0: Do not monitor
1: Monitor
* Some exceptions apply.
120 Network attribute 1
64
1
001H
Optional
Bits 4-11: I/O1 Fieldbus link error
confirmation timer value (10 ms)
Bits
12-15:
Registered module data size type in
PROFINET IO configuration
(0:1 word, 1:4 words)
Bits 28-31: Input Port Data Select in I/O1 Fieldbus
Link Error (0: Clear, 1: Hold)
121 Network attribute 2
C80000H
Optional
Bits 16-27: Link timeout value in Fieldbus
initialization (100 ms)
130 I/O Fieldbus
Own MAC address (H)
0H
MAC
address
display
Only lower two bytes are valid.
131 I/O Fieldbus
Own MAC address (L)
0H
MAC
address
display
225 I/O controller
AH
AH
Bits 0-7: Type of Network I/F Module Control 1
(0H
:
Not mounted,
1H
:
CC-Link,
2H
:
DeviceNet,
3H
:
PROFIBUS-DP,
6H
:
EtherCAT,
7H
:
EtherNet/IP,
9H
:
PIO,
AH
:
PROFINET IO,
DH
:
CC-Link IE)
Input port No.0 to 15
Output port No.300 to 315
6.3 Parameter Configuration
ME0392-4C
6-93
PROFINET IO + PIO
●
Example of Use (1)
It is the setting when PROFINET IO is to be used for 256 points of each input and output from
the top of the extension input and output ports (No. 1,000 ~, No. 4,000 ~), and PIO is to be
used for 48 points of each input and output from the top of the input and output ports (No. 0 ~,
No. 300 ~).
In this case, three units of PIO units (16 points x 3 units = 48 points) should be used.
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
1
I/O port assignment type
1
0
0: Fixed assignment
1: Automatic assignment
14
Number of Ports Used for
I/O1 Fieldbus Remote Input
0
256
Multiple of 8
15
Number of Ports Used for
I/O1 Fieldbus Remote Output
0
256
Multiple of 8
16
I/O1 fix-allocated input port
start No.
-1
1,000
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set.)
17
I/O1 fix-allocated output port
start No.
-1
4,000
300 + (multiple of 8) (300 to 599)
4,000 + (multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set.)
18
I/O1 error monitor
1
1
0: Do not monitor
1: Monitor
* Some exceptions apply.
20
Input filtering periods
2
2
ms
Input signal is recognized when the status is
held for twice the period set by this parameter.
* Valid only for PIO, PIO unit /
PIO/SIO unit
120 Network attribute 1
641001H
Optional
Bits 4-11: I/O1 Fieldbus link error
confirmation timer value (10 ms)
Bits
12-15:
Registered module data size type in
PROFINET IO configuration
(0:1 word, 1:4 words)
Bits 28-31: Input Port Data Select in I/O1 Fieldbus
Link Error (0: Clear, 1: Hold)
121 Network attribute 2
C80000H
Optional
Bits 16-27: Link timeout value in Fieldbus
initialization (100 ms)
130 I/O Fieldbus
Own MAC address (H)
0H
MAC
address
display
Only lower two bytes are valid.
Extension input port No.1,000 to 1,256
Extension output port No.4,000 to 4,256
Input port No.0 to 47
Output port No.300 to 347
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......