Chapter 3 Specifications for each unit
3.4 200V Driver Unit, Fan Unit for 200V Driver
3-82
ME0392-4C
[Cable for Driver Stop Feature]
(Sold separately)
Model Code
Cable Model
Wiring Diameter
CB-SC-
STO□□□
2464C BIOS-CL3-2603P-B (BANDO DENSEN) AWG26×3P
[Dummy Plug for Driver Stop Connector] (Enclosed)
It is a short-circuit plus to unable the function by connecting to the driver stop connector when the
driver stop feature is not in use.
[Driver Stop Connector (Cable Side)] (To be prepared by user)
There is the following model code available for a connector unit on the cable side when a cable
for driver stop feature is to be built up.
Manufacturer: Tyco Electronics
Model Code: 2013595-1 (Soldering Type) * There is cold-welding type also available.
It is necessary to have a cramping tool 2229737-1 (for both soldering and cold-
welding types).
Model : DP-6
Cramping Tool
2229737-1
Controller Side Connector Name
:
2013595-1
(
Tyco Electronics
)
Pin No.
Signal Name
Wiring
Color
1
-
AWG26
-
2
-
-
3
/SRI1-
Black
4
/SRI1+
Black/ White
5
/SRI2-
Red
6
/SRI2+
Red/ White
7
EDM-
Green
8
EDM+
Green/ White
Cut off
3.5 SCON Extension Unit, PIO/SIO/SCON Extension Unit, PIO Unit
ME0392-4C
3-83
SCON
extension unit
200V
Teaching tool
Power supply unit
Model :
PSA-24
RCS/ISB/DDA, etc.
SCON-CB
Field network / PIO
Fan unit
Model :
RCON-FU
RCON-FUH
RCP
RCD
RCA•RCL
Simple absolute unit
RCP/RCA
Model :
(for stepper motor)
Model :
(for AC servo motor)
PLC
Connectable actuators
RCS/ISB
/DDA, etc.
24V
Model :
RCON-EXT
RCON-EXT-NP/PN
PIO unit
Model :
IA-101-X
IA-101-N
Model :
TB-02
TB-03
SCON
extension unit and
PIO/SIO/SCON
extension unit
3.5 SCON Extension Unit, PIO/SIO/SCON Extension Unit, PIO Unit
3.5.1 Overview
[SCON extension unit]
SCON extension unit is a unit to connect SCON-CB Controller to RSEL system.
Using the SCON extension unit and SCON-CB Controller should enable to connect actuators
that are not capable to connect with the 200V driver unit (RCON-SC).
As seen from the front, the SEL unit is placed to the left end of the RSEL system, while the
expansion unit is located on the right side of the SEL unit during use.
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......