Chapter 3 Specifications for each unit
3.4 200V Driver Unit, Fan Unit for 200V Driver
3-78
ME0392-4C
3.4.6 Driver stop circuit
The 200V driver unit (RCON-SC0 possesses a drive cutoff circuit and the driver stop circuit by
the internal semiconductor instead of an external drive cutoff connector.
The driver stop circuit (DRV STOP) is a feature that cuts off the energy supply to the motor by the
cutoff circuit in the controller after a reaction time (8ms or less) in response to the input signal and
makes a safe stop.
Shown below is an example for wiring for the driver stop feature.
[Connector Position]
Driver Stop Connector
Front View of RCON-SC
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......