Chapter 6 Field Network, PIO, SIO
6.5 Example of Connectivity Setting
6-114
ME0392-4C
Edit the process data size of input and output in “Edit PDO Map Settings” window.
■
When the input of the process data size do not match with the setting in I/O Parameter
No. 15 (Number of ports used for I/O1 fieldbus remote output) of RSEL controller.
(1) Select “Input” from the PDO mapping list, and delete the PDO entries till the input of
the process data size matches with Parameter No. 15 “Number of ports used for I/O1
fieldbus remote output” in RSEL Controller.
Select the PDO entries in the descending order of the index from “PDO entries
included in In”, and click Delete PDO Entry .
3
Delete in descending
order of index
Two values do not match
6.5 Example of Connectivity Setting
ME0392-4C
6-115
(2) Once the input of the process data size matches with Parameter No. 15 “Number of ports
used for I/O1 fieldbus remote output” in RSEL Controller, click Apply .
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......