Chapter 6 Field Network, PIO, SIO
6.3 Parameter Configuration
6-98
ME0392-4C
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
189 PIO Unit / PIO/SIO Unit Error
Monitor
1
1
0: Not monitored
1: Monitored
2: Monitored (24V I/O power supply related errors
not monitored)
3: Monitored (only 24V I/O power supply related
errors monitored)
4: Monitored (24V I/O power supply related errors
output as message level)
* Some exceptions apply
190 Option Unit Attribute 1
C800200H Optional
Bits 0 to 3: PIO unit output port data select in TF
connection error (0: Clear, 1: Hold)
Bits 4 to 7: PIO unit input port data select in TF
connection error (0: Clear, 1: Hold)
Bits 8 to 15: TF communication link error check timer
value (10 ms)
Bits 20 to 31: Link timeout value in TF
communication initialization (100 ms)
225 I/O controller
9H
9H
Bits 0-7: Type of Network I/F Module Control 1
(0H
:
Not mounted,
1H
:
CC-Link,
2H
:
DeviceNet,
3H
:
PROFIBUS-DP,
6H
:
EtherCAT,
7H
:
EtherNet/IP,
9H
:
PIO,
AH
:
PROFINET IO,
DH
:
CC-Link IE)
6.3 Parameter Configuration
ME0392-4C
6-99
●
Example of Use (2)
It is the setting when PIO is to be used for 64 points of each input and output from the top of
the input and output ports (No. 0 ~, No. 300 ~). The following setting is an example of not
using a PIO module and using three units of PIO units (16 points x 3 units = 48 points) should
be used.
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
1
I/O port assignment type
1
0
0: Fixed assignment
1: Automatic assignment
16
I/O1 fix-allocated input port
start No.
-1
16
0 + (Multiple of 8) (0 to 299)
(Invalid if a negative value is set.)
17
I/O1 fix-allocated output port
start No.
-1
316
300 + (multiple of 8) (300 to 599)
(Invalid if a negative value is set.)
18
I/O1 error monitor
1
1
0: Not monitored
1: Monitored
2: Monitored (24V I/O power supply related errors
not monitored)
3: Monitored (only 24V I/O power supply related
errors monitored)
4: Monitored (24V I/O power supply related errors
output as message level)
* Only PIO available for setting in 2 to 4
* Some exceptions apply
20
Input filtering periods
2
Optional
ms
Input signal is recognized when the status is
held for twice the period set by this parameter.
* Valid only for PIO, PIO unit /
PIO/SIO unit
186
Number of Connected option
unit
0
3
unit
The number of ports used for input and output
should be number of connected units × 16 for each.
187
Option unit fix-allocated input
port start No.
-1
48
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set)
188
Option unit fix-allocated
output port start No.
-1
348
300 + (Multiple of 8) (300 to 599)
4,000 + (Multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set)
189 PIO Unit / PIO/SIO Unit Error
Monitor
1
1
0: Not monitored
1: Monitored
2: Monitored (24V I/O power supply related errors
not monitored)
3: Monitored (only 24V I/O power supply related
errors monitored)
4: Monitored (24V I/O power supply related errors
output as message level)
* Some exceptions apply
Input port No.0 to 191
Output port No.300 to 491
Input port No.192 to 239
Output port No.492 to 539
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......