Chapter 3 Specifications for each unit
3.1 SEL Unit, Terminal Unit
3-24
ME0392-4C
●
EtherNet/IP
Connector type
8P8C
modular c
onnector
Cable recommended
Enhanced Category 5 or above
LED
name
Color
Status
Content
MS
Green
Light ON
In operation condition and under control of scanner
(master)
Blinking
Setting of construction information incomplete, or
scanner (master) in idling condition
Orange
Light ON
Fatal malfunction (exception condition or critical error)
Blinking
Light malfunction possible to recover
Green/orange
Light OFF
Turned off.
NS
Green
Light ON
Online status
(Connection established on one or more)
Blinking
Online status (connection not being established)
Orange
Light ON
Critical error such as IP address duplication
Blinking
Timeout in connection on one or more
Green/orange
Light OFF
Turned off, IP address not set
NS
MS
3.1 SEL Unit, Terminal Unit
ME0392-4C
3-25
●
PROFIBUS-DP
Connector type
D-sub Connector 9-pin (Socket)
Pin No.
Signal name
Description
1
NC
Not connected
2
NC
Not connected
3
B-Line
Signal line B (RS-485)
4
RTS
Transmission request
5
GND
Signal GND (insulation)
6
+5V
+5 V output (isolated)
7
NC
Not connected
8
A-Line
Signal line A (RS-485)
9
NC
Not connected
Housing
Shield
Cable s
hield
(Connected with FG inside controller)
LED name
Color
Status
Content
MS
Green
Light ON
Initialization complete
Blinking
Initialization complete (diagnosis event found)
Orange
Light ON Error occurrence
(Exception error)
NS
Green
Light ON
Online status
Blinking
Online status (clear status)
Orange
Light ON Error occurrence
(
Parameter error,
PROFIBUS
Configuration information error
)
1
5
NS
MS
6
9
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......