Chapter 9 Special Functions
9.3 Preventive Maintenance Function
9-14
ME0392-4C
[Maintenance Information Setting in Teaching Tool]
Maintenance information can be checked and set with the following procedures.
• TB-02/TB-
03 [Monitor] → [Maintenance]
• TB-02/TB-
03 [Information] → [Maintenance Information]
• PC software [Monitor (M)] → [Maintenance Information (I)] → Axis selection
As a reference, shown below is how to operate using a teaching pendant TB-02.
Refer to an instruction manual for each teaching tool for detail.
● Switchover to Maintenance Information
Screen Using TB-02
Touch Information on the Menu 1 screen.
The screen will switch to the Information screen.
If the TP operation mode is not Monitor mode,
a confirmation screen will appear for
switching to Monitor mode.
Touch Maintenance information on the
Information screen.
The maintenance information screen opens.
2
1
Action
Action
9.3 Preventive Maintenance Function
ME0392-4C
9-15
● Basic Operation in Maintenance Information
Screen Using TB-02
To set the target value,
touch the Edit button of the relevant item.
The set value will blink and Ten Key
screen will open.
Enter the value with the Ten Key pad
and touch the ENT key.
• The target value will change.
If you touch ESC ,
the target value will not be changed and
the original screen will return.
• A confirmation message will be displayed
to reboot the controller when leaving the
maintenance screen.
The setting change will take effect
after rebooting.
If the actuator has been replaced,
touch the Actuator replacement button.
“Total travel count” and “Total travel distance”
will be cleared to “0”.
1
Action
2
Action
3
Action
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......