Chapter 6 Field Network, PIO, SIO
6.3 Parameter Configuration
6-60
ME0392-4C
6.3.4 Example of use of each network and parameter
[1] CC-Link only
It is the setting when CC-Link is to be used for 16 points of each input and output from No. 0
and from No. 300 of the input and output ports.
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
1
I/O port assignment type
0
0
0: Fixed assignment
1: Automatic assignment
14
Number of Ports Used for
I/O1 Fieldbus Remote Input
64
16
Multiple of 8
15
Number of Ports Used for
I/O1 Fieldbus Remote Output
64
16
Multiple of 8
16
I/O1 fix-allocated input port
start No.
0
0
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set.)
17
I/O1 fix-allocated output port
start No.
300
300
300 + (multiple of 8) (300 to 599)
4,000 + (multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set.)
18
I/O1 error monitor
1
1
0: Do not monitor
1: Monitor
* Some exceptions apply.
120 Network attribute 1
64
10
01H
Optional
Bits4-11: I/O1 Fieldbus link error
confirmation timer value (10 ms)
Bits28-31: Input Port Data Select in I/O1 Fieldbus
Link Error (0: Clear, 1: Hold)
121 Network attribute 2
C80000H
Optional
Bits 16-27: Link timeout value in Fieldbus
initialization (100 ms)
225 I/O controller
1H
1H
Bits 0-7: Type of Network I/F Module Control 1
(0H
:
Not mounted,
1H
:
CC-Link,
2H
:
DeviceNet,
3H
:
PROFIBUS-DP,
6H
:
EtherCAT,
7H
:
EtherNet/IP,
9H
:
PIO,
AH
:
PROFINET IO,
DH
:
CC-Link IE)
226 I/O1 Fieldbus Node Address
1
Optional
Settable Range
1 to 64
227 I/O1 Fieldbus communication
speed
4
Optional
0: 156kbps, 1: 625kbps, 2: 2.5Mbps, 3: 5Mbps,
4: 10Mbps
Input port No.0 to 15
Output port No.300 to 315
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......