
Chapter
11 T
roubleshooting
11.3 Error List
11-29
ME0392-4C
Error
No.
Error name
Content and Cause /
Countermeasure
O
per
at
io
n-
can
cel
lat
ion
419
SIO incorrect OPEN
command usage error
[Content & Cause]
1) Parameter setting error
• There is a mismatch between the setting in I/O Parameter No. 90
Free-to-User SIO Channel Use and the actual way to use
[Countermeasure]
1) Check the setting in I/O Parameter No. 90 Free-to-User SIO Channel Use
0: SEL Program Release
1: SEL Program Release (Common in devices PC/TP connection at
CLOSE)
2:IAI Protocol B (Slave)
41A
Error of communication
channel# opened to
users
[Content & Cause]
1) An unsupported channel number was indicated in OPEN Command
[Countermeasure]
1) A supported channel number should be indicated in OPEN Command
SIO connection connector : Channel No. 0 or 1
Ethernet connector : Channel No. 31 to 34
41B
SCHA command setting
error
[Content & Cause]
1) Setting error in SCHA Command
[Countermeasure]
1) Check SCHA Command setting
41C
TPCD command setting
error
[Content & Cause]
2) Setting error in TPCD Command
[Countermeasure]
1) Check TPCD Command setting
41D
SLEN command setting
error
[Content & Cause]
1) Setting error in SLEN Command
[Countermeasure]
1) Check SLEN Command setting
41E
ECMD 300 command
error
[Content & Cause]
1) User system error output command (ECMD300) was executed
[Countermeasure]
1) Check the programs using the user system error output command
41F
Error detail inquiry type
error
[Content & Cause]
1) A command creation error from a host program such as touch panel
[Countermeasure]
1) Check the host program and send an appropriate command
420
Operand error
[Content & Cause]
1) Operand indication error
2) Operand data is invalid
3) Operand data type error
[Countermeasure]
1) Check the operand indication in the program step that the error
occurred
2) Check the operand data in the program step that the error occurred
3) Check the operand data type in the program step that the error
occurred
11.3 Error List
ME0392-4C
11-30
Error
No.
Error name
Content and Cause /
Countermeasure
O
per
at
io
n-
can
cel
lat
ion
421
No. of running programs
exceeded the limit
[Content & Cause]
1) Programs exceeding the number of programs available to be executed
at the same time were executed
[Countermeasure]
1) Check the programs and avoid exceeding the number of programs
available to be executed at the same time
422
Program 1st step BGSR
error
[Content & Cause]
1) A program to be executed was started with BGSR
[Countermeasure]
1) Check the program and avoid starting it with BGSR
423
Executable step non-
detection error
[Content & Cause]
1) The program specified for execution does not contain executable
program steps.
[Countermeasure]
1) Execute a program with available program steps or register available
program steps to a program number that is to be executed
424
DW/IF/IS/SL pair end
error
[Content & Cause]
1) There was an error in a treatment to the branch instruction appeared
previously
2) EDIF, EDDO and EDSL were not found
[Countermeasure]
1), 2) Check the treatment to IF/IS Commands and EDIF
Check the treatment to DO Command and EDDO
Check the treatment to SLCT Command and EDSL
425
BGSR pair end
insufficient error
[Content & Cause]
1) There was lack in EDSR corresponding to BGSR
2) There was lack in BGSR corresponding to EDSR
[Countermeasure]
1), 2) Check the treatment of BGSR and EDSR
426
DO/IF/IS nesting step
times error
[Content & Cause]
1) The number of nesting times in DO Command and IF/IS Commands
has exceeded the limit
[Countermeasure]
1) Check the program and see if there is an excess number of nesting
times or branch into the grammatical construction or out of the
grammatical construction in GOTO Command
427
SLCT nesting steps
exceeded
[Content & Cause]
1) The number of nesting times in SLCT Command has exceeded the limit
[Countermeasure]
1) Check the program and see if there is an excess number of nesting
times or branch into the grammatical construction or out of the
grammatical construction in GOTO Command
428
Sub-routine nesting time
exceeded
[Content & Cause]
1) The number of nesting times in the sub-routine call has exceeded the
limit
[Countermeasure]
1) Check the program and see if there is an excess number of nesting
times or branch into the grammatical construction or out of the
grammatical construction in GOTO Command
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......