Chapter 4 Unit connection / In
stallation and Wiring
4.4
Wiring Method
4-20
ME0392-4C
[1] Wiring to DC Power Supply for Motor Drive
(1) Refer to the table below for the wire diameter for
each cable.
(2) The stripped length on a cable should be 7 mm.
(3) Insert wires to the inlet on the power supply connector.
Inset the wires till they hit the end.
(4) Tighten up the terminal screw with using a slotted
screwdriver.
Inlet
Wire
Motor power connector
(Model : MSTB2.5/6-STF-5.08)
Terminal Screw
7 mm
Screwdriver
• Motor power supply (L1 and L2)
• Control power supply (L1C and L2C)
• Ground (PE)
Perform wiring at 5 points in total
Screwdriver
Bad Good
0 7
mm