Chapter 10 Parameter
10.2 Parameter List (SEL Unit)
4. Axis parameters
10-38
ME0392-4C
No.
Parameter name
Setting at
Delivery Input range
Unit
Remarks
22 Zone1 Negative Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
23 Zone 1 Output No.
0
0 to 6,999
Physical output port or Global Flag or Extended
Output Ports
(Output invalid when set to 0, invalid when
duplicated)
24 Zone2 Positive Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
25 Zone2 Negative Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
26 Zone 2 Output No.
0
0 to 6,999
Physical output port or Global Flag or Extended
Output Ports
(Output invalid when set to 0, invalid when
duplicated)
27 Zone3 Positive Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
28 Zone3 Negative Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
29 Zone 3 Output No.
0
0 to 6,999
Physical output port or Global Flag or Extended
Output Ports
(Output invalid when set to 0, invalid when
duplicated)
30 Zone4 Positive Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
31 Zone4 Negative Side
0
-99,999,999
to
99,999,999
0.001mm
Only Positive side > Negative side valid
* Necessary to secure 3 ms or more for domain
going-through time
32 Zone 4 Output No
0
0 to 6,999
Physical output port or Global Flag or Extended
Output Ports
(Output invalid when set to 0, invalid when
duplicated)
33 Output Number while Servo-on
0
0 to 6,999
Physical output port or Extended Output Ports
(Output invalid when set to 0, invalid when
duplicated)
34 In-Position Output Number
0
0 to 6,999
Physical output port or Extended Output Ports
(Output invalid when set to 0, invalid when
duplicated)
* Output off when pressing missed
35 (For expansion)
0
to
36 Reserved by the system
100
50 to 100
%
37
OLWNO
Driver overload warning
output No
0
0 to 6,999
Physical output port or Extended Output Ports
(Output invalid when set to 0, invalid when
duplicated)
* Contact b
38
to
40
(For expansion)
0
to
10.2 Parameter List (SEL Unit)
4. Axis parameters
ME0392-4C
10-39
No.
Parameter name
Setting at
Delivery Input range
Unit
Remarks
41
Axis Select for Appliance of
Multi-Slider Over Approach
Detection
0H
0H to
FFFFFFFFH
Bits 0 to 3: Mating axis number to apply over
approach detection (self-axis coordinate
positive movement side)
Bits 4 to 7: Mating axis number to apply over
approach detection (self-axis coordinate
negative movement side)
* Necessity of mutual input with mating
axis (The smaller axis number in a pair
is the multi-slider master axis for
convenience.)
* Axes with same characteristics on
resolution related are available to
select.
* Make sure to select the synchro-master
axis when synchronizing type
(forbidden to select synchro-slave
axes).
* Set to 0 when there is no slider close to
the side of applicable movement of the
self-axis coordinate.
42
Emergency Deceleration
Margin at Multi-Slider Over
Approach
5
0 to 999
0.01G
43 Multi-Slider Setting Bit Pattern 1
12H
0H to
FFFFFFFFH
Bits 0 to 3: Multi-slider actual position over approach
detection margin [mm]
(Valid only on multi-slider master axis
parameters)
Bits 4 to 7: Multi-slider commanded position over
approach detection margin [mm]
(Valid only on multi-slider master axis
parameters)
44 (For expansion)
0
to
45 NTCH
初期値
0
0 to 3
Initial value in anti-vibration control parameter set
number
(Main application part V1.09 or later)
* Setting not available for axed not supporting anti-
vibration control
* The settings in master axis to be reflected to both
master axis and slave axis when synchronizing
control is activated
46
to
200
(For expansion)
0
to
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......