Chapter 6 Field Network, PIO, SIO
6.3 Parameter Configuration
6-98
ME0392-4C
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
189 PIO Unit / PIO/SIO Unit Error
Monitor
1
1
0: Not monitored
1: Monitored
2: Monitored (24V I/O power supply related errors
not monitored)
3: Monitored (only 24V I/O power supply related
errors monitored)
4: Monitored (24V I/O power supply related errors
output as message level)
* Some exceptions apply
190 Option Unit Attribute 1
C800200H Optional
Bits 0 to 3: PIO unit output port data select in TF
connection error (0: Clear, 1: Hold)
Bits 4 to 7: PIO unit input port data select in TF
connection error (0: Clear, 1: Hold)
Bits 8 to 15: TF communication link error check timer
value (10 ms)
Bits 20 to 31: Link timeout value in TF
communication initialization (100 ms)
225 I/O controller
9H
9H
Bits 0-7: Type of Network I/F Module Control 1
(0H
:
Not mounted,
1H
:
CC-Link,
2H
:
DeviceNet,
3H
:
PROFIBUS-DP,
6H
:
EtherCAT,
7H
:
EtherNet/IP,
9H
:
PIO,
AH
:
PROFINET IO,
DH
:
CC-Link IE)
Summary of Contents for R-unit RSEL
Page 2: ......
Page 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Page 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Page 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Page 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Page 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Page 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Page 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Page 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Page 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Page 843: ......
Page 844: ......