Oct 8 09:26:25: %RPM1:RP1 %BGP-5-ADJCHANGE: Connection with neighbor 1.1.14.2
closed. Neighbor recycled
--More--
Example (History)
Dell#show logging history
Syslog History Table: 1 maximum table entries,
saving level Warnings or higher
SNMP notifications not Enabled
%RPM:0:0 %CHMGR-2-LINECARDDOWN - Line card 3 down - IPC timeout
Dell#
show logging driverlog stack-unit
Display the driver log for the specified hardware component.
Syntax
show logging driverlog stack-unit
stack-unit-number
Parameters
stack-unit
stack-
unit-number
Enter the keywords
stack-unit
followed by the stack member ID of the switch for
which you want to display the driver log.
defaults
none
Command Modes
•
EXEC
•
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant
Dell Networking
OS Command Line Reference Guide
.
Version
Description
9.10(0.0)
Introduced on the S6100–ON.
9.8(1.0)
Introduced on the Z9100–ON.
9.8(0.0P5)
Introduced on the S4048-ON.
9.8(0.0P2)
Introduced on the S3048-ON.
9.7(0.0)
Introduced on the S6000-ON.
9.2(1.0)
Introduced on the Z9500.
9.2(0.0)
Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux
(PMUX) mode only.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
Example
Dell#show logging driverlog stack-unit 1
0:Task(tUsrRoot): [ 491677]PSU FanCtrl Drv ERR:
ssnDrvPoePsuEepromWriteEnable : 66 - Psu 1 is Not Present Cannot enable
1:Task(tUsrRoot): [ 338]PSU FanCtrl Drv ERR: ssnDrvPsuFanCtrlInit : 118 -
1538
Simple Network Management Protocol (SNMP) and Syslog