MPH-02, MPB-02, MPD-02
Drive Functions
8-3
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
DK000040v02_en.fh7
t
t
v
t
t
S-0-0372
t
1
control word
(P-0-0116; bit 13)
standstill window
(S-0-0124)
activation "Drive Halt" (AH)
AH
AF
AF
diagnostic
message
acknow-
ledgment
"Drive Halt"
(P-0-0115; bit 4)
t
1
S-0-0372:
Drive Halt acceleration bipolar
Fig. 8-2:
Principle of "Drive Halt" with velocity control active before
Notes on Commissioning
The activated "Drive Halt" function is displayed as described below:
•
"AH" appearing on the control panel display at the front of the device
•
"A0010" entered in parameter
S-0-0390, Diagnostic message
number
•
"A0010 Drive HALT" entered in parameter
S-0-0095, Diagnostic
message
•
in bit "status of command value processing" in status word of master
communication (e.g. with SERCOS: bit 3 = 0 in
S-0-0135, Drive
status word
)
An acknowledgment is carried out when the actual velocity falls below the
threshold defined in parameter
S-0-0124, Standstill window
. Bit 4
(acknowledgment Drive Halt) is then set in the drive in parameter
P-0-0115, Device control: status word
.