7-42
Operating Modes
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
•
P-0-4006, Process block target position
•
P-0-4007, Positioning block velocity
•
P-0-4008, Positioning block acceleration
•
P-0-4009, Positioning block jerk
•
P-0-4019, Positioning block mode
•
P-0-4026, Positioning block selection
•
P-0-4051, Positioning block acknowledgment
•
P-0-4052, Positioning block, last accepted
•
P-0-4053, Positioning block, last active
•
P-0-4057, Positioning block, input linked blocks
•
P-0-4060, Positioning block control word
•
P-0-4061, Positioning block status word
•
P-0-4063, Positioning block deceleration
Note:
Parameter S-0-0259 is used in positioning block mode to
reduce positioning velocity (see also
P-0-4060, Positioning
block control word
).
Pertinent Diagnostic Messages
•
A0206 Positioning block mode, encoder 1
•
A0207 Positioning block mode lagless, encoder 1
•
A0210 Positioning block mode, encoder 2
•
A0211 Positioning block mode lagless, encoder 2
•
E2047 Interpolation velocity = 0
•
E2048 Interpolation acceleration = 0
•
E2049 Positioning velocity >= S-0-0091
•
E2053 Target position out of travel range
•
E2054 Not homed
•
E2055 Feedrate override S-0-0108 = 0
•
E2058 Selected process block is not programmed.
•
E2064 Target position out of num. range
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com