11-8
Commissioning
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
1.Er.Anz
3 P2
standard display
"Enter" button
extended display
2.Comand
"Up" button
commands/settings
"Enter" button
2.8 >CP4
2.1 Adr.
Adr. 3
"Enter" button
automatic return
to standard
display
3 bb
activating the
parameterization
mode
It is possible to
switch power on!
Y.Y
XXXXXXXX
explanation:
display changes (flashes) between
"Y.Y" and "XXXXXXXX"
"Down" button
=> CP 4
e.g.:
Fig. 11-4:
Switching the drive in the "easy startup" mode" back from the
parameterization mode to "ready for operation" via the control panel
The "easy startup" mode can only be terminated by switching the
controller off!
When the controller is switched on again it first is in its original state. If the
"easy startup" mode is required again, it has to be activated again.
Notes on Commissioning
CAUTION
Danger of property damage during initial start in
the "easy startup" mode caused by incorrect
parameter values!
⇒
For motors without encoder data memory, the initial
start in the "easy startup" mode during initial
commissioning is not allowed because the automatic
adjustment of the controller to the motor is
impossible!
•
During initial commissioning the initial start in the "easy startup" mode
is only allowed for motors with encoder data memory!
•
For serial commissioning (parameter values determined by initial
commissioning are already stored in the controller) the initial start in
the "easy startup" mode is possible for motors with and without
encoder data memory!
Steps to follow for the initial start in the "easy startup" mode during initial
commissioning:
1. Connect power supply of inputs/outputs (X31/X32) with 24V/0V, then
switch control voltage on.
2. When drive displays communication phase "P2", activate "easy
startup" mode via buttons of control panel: "Enter"
→
"Up"
→
"Enter"
→
"Up"
→
"Up"
→
"Enter"
→
"Enter"
Activated "easy startup" mode is displayed for a short time with the
letters "Easy-ON". Then the operating status message "bb" will be
displayed (see also fig. "Activating the "easy startup" mode").
Terminating the "Easy Startup"