4-48
Master Communication
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Without considering a fragmentation or an error, the parameter channel
when
writing a parameter
is made up of:
Control word
Index
Sub-index
Data
M
→
S
2 bytes
2 bytes
2 bytes
max. 80
bytes
Status word
S
→
M
2 bytes
Without considering a fragmentation, the parameter channel when
reading a parameter
is made up of:
Control word
Index
Sub-index
M
→
S
2 bytes
2 bytes
2 bytes
Status word
Data
S
→
M
2 bytes
max. 80 bytes
The control unit defines the basic setting and the drive responds with the
identifier (2 bytes) of the supported parameter channel format; in this
case with 01V00.
Control word/status word
User data
Res
G/F
L
T
FL
GL
B2
B3
B4
B5
B6
B7
B8
B9
M
→
S
0
1
1
0/1
0
0
-
-
-
-
-
-
-
-
S
→
M
0
0
1
0/1
2
2
01h
00h
-
-
-
-
-
-
Fig. 4-25:
Basic setting for parameter channel
The control unit reads the operating data of parameter S-0-0057. It is a
double word, fragmentation therefore is not necessary.
The value is 100.
Parameter mapping:
•
index
=
2039h
•
sub-index
=
7h
Control word/status word
User data
Res
G/F
L
T
FL
GL
B2
B3
B4
B5
B6
B7
B8
B9
M
→
S
0
1
1
1/0
4
4
20h
39h
00h
07h
-
-
-
-
S
→
M
0
0
1
1/0
4
4
00h
00h
00h
64h
-
-
-
-
Fig. 4-26:
Non-fragmented reading
Basic Setting
Non-Fragmented Reading
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com