MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-15
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Note:
The control password valid for the respective firmware is only
available from the manufacturer on demand!
The master password is defined by the manufacturer, too, but is
exclusively available to the Bosch Rexroth development and service staff.
Note:
The master password is secret! It mustn’t be used on the
control unit side or by the customer, because it also allows
changing the values of "administration parameters" (motor
parameters, hardware code parameters, encoder parameters,
error memory, etc.).
In the condition as supplied the
S-0-0267, Password
parameter contains
the value "007". The write protection is activated and deactivated by
means of the customer password according to the following procedure:
FS0212f1.fh7
_: space
input:
customer password
input:
any string
without space
or switch-off
input string:
007_Kpassw_Kpassw
Kpassw.:customer password
input string:
Kpassw_007_007
customer password active and unlocked
parameter can be written,
content S-0-0267: "
$$$
"
no customer password active
parameter can be written,
content S-0-0267: "007"(default status)
customer password active and locked
parameter write-protected,
content S-0-0267:
"***"
Fig. 10-2:
Activating and deactivating the write protection by means of the
customer password
The write protection activated via customer password is deactivated by
means of the control password by entering the control password in
S-0-0267. The write protection required by the customer can be activated
again by entering any string in S-0-0267.
The write protection for all parameters that can basically be written can
only be deactivated by means of the master password and the right to do
this is exclusively reserved to the Bosch Rexroth development and
service staff!
Master Password
Activating/Deactivating the Write
Protection