MPH-02, MPB-02, MPD-02
Extended Drive Functions
9-41
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Notes on Commissioning
Presettings for the analog output have to be made in
P-0-0427, Control
parameter of analog output
:
•
setting the mode (drive-independent voltage signals or assigned
parameters)
•
determining limitation or overflow with regard to the voltage value
•
setting the output clock
With mode "assigning parameters" selected, make assignment in
•
P-0-0420, Analog output, assignment A, signal selection
.
Determine voltage range of signal to be output per 1 V in
•
P-0-0422, Analog output, assignment A, scaling [1/V]
.
Preset signal value at which voltage "0V" is output in
•
P-0-0418, Analog output, assignment A, signal value at 0V
.
The voltage to be output at the analog output is displayed in
•
P-0-0139, Analog output 1
.
Combining the Parameters for the Respective Analog
Output
•
P-0-0139, Analog output 1
•
P-0-0418, Analog output, assignment A, signal value at 0V
•
P-0-0420, Analog output, assignment A, signal selection
•
P-0-0422, Analog output, assignment A, scaling [1/V]
•
P-0-0140, Analog output 2
•
P-0-0419, Analog output, assignment B, signal value at 0V
•
P-0-0423, Analog output, assignment B, signal selection
•
P-0-0425, Analog output, assignment B, scaling [1/V]
•
P-0-0414, Analog output 3
•
P-0-0418, Analog output, assignment A, signal value at 0V
•
P-0-0420, Analog output, assignment A, signal selection
•
P-0-0422, Analog output, assignment A, scaling [1/V]
•
P-0-0415, Analog output 4
•
P-0-0419, Analog output, assignment B, signal value at 0V
•
P-0-0423, Analog output, assignment B, signal selection
•
P-0-0425, Analog output, assignment B, scaling [1/V]
Settings for Analog Output 1,
For Example
Analog Output 1
Analog Output 2
Analog Output 3
Analog Output 4