6-92
Drive Control
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
CAUTION
Property damage caused by inadmissibly high
voltage on the motor terminals!
⇒
For third-party motors the maximum allowed terminal
voltage has to be observed!
Diagnostic and Status Messages
Displaying module bus status:
•
P-0-0461, Module group, status word
Displaying device-side module bus control information:
•
P-0-0460, Module group, control word
Displaying interrupted module bus communication:
•
F2087 Module group communication error
Mains voltage diagnoses:
•
P-0-0806, Current mains voltage crest value
•
P-0-0815, Nominal mains voltage crest value
Mains voltage warnings:
•
E2814 Undervoltage in mains
•
E2818 Phase failure
•
E2819 Mains failure
Mains voltage error messages:
F2814 Undervoltage in mains
F2816 Softstart fault power supply unit
F2818 Phase failure
•
F2819 Mains failure
F2834 Contactor control error
F2840 Error supply shutdown
F2860 Overcurrent in mains-side power section
DC bus diagnosis:
S-0-0380, DC bus voltage
DC bus warnings:
•
E2026 Undervoltage in power section
•
E2026 Undervoltage in power section
•
E8025 Overvoltage in power section
DC bus error messages:
•
F2026 Undervoltage in power section
F2817 Overvoltage in power section
F2833 Ground fault in motor line
F2836 DC bus balancing monitor error
Module Bus
Mains Voltage
DC Bus
Courtesy