MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-35
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Starting from the extended display it is possible to activate commands
and make settings:
•
set the drive address (drive number in the bus system of the master
communication)
•
set the length of the fiber optic cable
•
activate the "analog mode" master communication
•
C07_x load defaults procedure command (loading controller
parameters resp. base parameters)
•
other commands like
•
C2200 Backup working memory procedure command
•
C2300 Load working memory command
•
C2500 Copy IDN from optional memory to internal memory
•
C2600 Copy IDN from internal memory to optional memory
•
C2900 Firmware update from MMC
Command Inputs