4-58
Master Communication
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Bit number in
signal control word
Digital input
of the parallel interface
0
X15 pin 1
1
X15 pin 20
2
X15 pin 2
3
X15 pin 21
4
X15 pin 3
5
X15 pin 22
6
X15 pin 4
7
X15 pin 23
8
X15 pin 5
9
X15 pin 24
10
X15 pin 6
11
X15 pin 25
12
X15 pin 7
13
X15 pin 26
14
X15 pin 8
15
X15 pin 27
Fig. 4-36:
Assignment of signal control word to digital inputs
See also "Configurable Signal Control Word" in chapter "Master
Communication"
Note:
Connector pin assignment is described in the separate
documentation "Project Planning Manual for Control Sections"
in chapter "Interfaces".
Configurable Digital Outputs
The signal status word for IndraDrive devices is cyclically generated or
cyclically transmitted to the I/O module:
•
cycle time "Advanced"
→
T = 250 µs
•
cycle time "Basic"
→
T = 500 µs
Note:
The bits of parameter
S-0-0144, Signal status word
are
mapped to the digital outputs of the parallel interface.
Bit number in
signal status word
Digital output
of the parallel interface
0
X15 pin 28
1
X15 pin 10
2
X15 pin 29
3
X15 pin 11
4
X15 pin 12
5
X15 pin 31
6
X15 pin 13
7
X15 pin 32
Cycle Time
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com