1-14
System Overview
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
3)
… optional module 2 (X8):
NNN
→
not equipped
EN1
→
encoder interface for HSF/resolver
EN2
→
encoder interface for EnDat/1Vpp sine/TTL signals
ENS
→
encoder interface for Rexroth standard/HIPERFACE/1Vpp
MA1
→
analog I/Os
MEM
→
encoder emulator
5)
… safety option (X41):
NN
→
not equipped
L1
→
starting lockout
The firmware
FWA-INDRV*-MPD-02VRS
for configurable
BASIC
UNIVERSAL double-axis control sections supports control
sections with the following type designations:
•
CDB01.1C-xx
1)
-xxx
2)
-xxx
3)
-xxx
4)
-xxx
5)
-xx
6)
-S-NN-FW
Possible types:
1)
… master communication, for both axes:
SE
→
SERCOS interface
PB
→
PPOFIBUS-DP
2)
… optional module 1 (X4.1), axis 1:
NNN
→
not equipped
EN1
→
encoder interface for HSF/resolver
EN2
→
encoder interface for EnDat/1Vpp sine/TTL signals
ENS
→
encoder interface for Rexroth standard/HIPERFACE/1Vpp
3)
… optional module 2 (X8.1), axis 1:
NNN
→
not equipped
EN1
→
encoder interface for HSF/resolver
EN2
→
encoder interface for EnDat/1Vpp sine/TTL signals
ENS
→
encoder interface for Rexroth standard/HIPERFACE/1Vpp
MA1
→
analog I/Os
MEM
→
encoder emulator
4)
… optional module 1 (X4.2), axis 2:
NNN
→
not equipped
EN1
→
encoder interface for HSF/resolver
EN2
→
encoder interface for EnDat/1Vpp sine/TTL signals
ENS
→
encoder interface for Rexroth standard/HIPERFACE/1Vpp
5)
… optional module 2 (X8.2), axis 2:
NNN
→
not equipped
EN1
→
encoder interface for HSF/resolver
EN2
→
encoder interface for EnDat/1Vpp sine/TTL signals
ENS
→
encoder interface for Rexroth standard/HIPERFACE/1Vpp
MA1
→
analog I/Os
MEM
→
encoder emulator
6)
… safety option, for both axes (X41.1 and X41.2):
NN
→
not equipped
L1
→
starting lockout
S1
→
module for safety technology
BASIC Double-Axis
(CDB01.1)
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪