5-10
Motor, Mechanical Axis System, Measuring Systems
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
released
applied
1
0
(AF internal)
DK000016v01_en.fh7
bit 3: 1
0
S-0-0207
motor
holding
brake
P-0-0115
bit 14: 1
0
bit 15: 1
0
AF from NC
AF reset by NC or error with "return motion"
error reaction
drive disables NC command values
actual velocity
value
S-0-0273
bit 1: 1
0
S-0-0013
bit 12: 1
0
target pos. reached
v
act
< S-0-0124
value of S-0-0124
t
Fig.
5-4:
Holding brake control with error situation
1 and braking
time < S-0-0273 ("return motion" error reaction)
If the drive cannot shut down the mechanical system within the time after
occurrence of the error entered in parameter S-0-0273, the motor holding
brake is controlled depending on the application (servo or main drive):