7-102
Operating Modes
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Phase Synchronization with Real/Virtual Master Axis
Brief Description
In the operating mode "phase synchronization with real/virtual master
axis" the drive follows a preset master axis position in an absolute or
relative phase synchronous way.
The real master axis position is generated by a master axis encoder, the
virtual master axis position is preset by the master.
See also "Dynamic Synchronization with Synchronous Position Control
Modes" in section "Basic Functions of the Synchronization Modes"
•
determination of the position command value from the master axis
position using the electronic gear and fine adjust, adjustable master
axis polarity
•
adjustable master axis cycle and actual value cycle, displayed
command value cycle
•
synchronization mode to be selected
•
standard
(trapezoidal)
•
register controller (PT1 filter)
•
additive master axis position
•
absolute and modulo processing of the master axis
•
absolute or relative phase synchronization
•
synchronization range to be selected
•
modulo
range
•
command value cycle
•
part of command value cycle
•
additive position command value
There are the following variants of the operating mode to be selected:
•
phase synchronization with real master axis, encoder 1
•
phase synchronization with real master axis, encoder 2
•
phase synchronization with real master axis, encoder 1, lagless
•
phase synchronization with real master axis, encoder 2, lagless
•
phase synchronization with virtual master axis, encoder 1
•
phase synchronization with virtual master axis, encoder 2
•
phase synchronization with virtual master axis, encoder 1, lagless
•
phase synchronization with virtual master axis, encoder 2, lagless
Features
Variants of the Operating Mode
Expansion package
synchronization
(order code
SNC
) in
closed-loop
characteristic