MPH-02, MPB-02, MPD-02
Operating Modes
7-45
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
With parameter
P-0-4060, Positioning block control word
(bit 1) the
positioning velocity can be limited to the value defined in parameter
S-0-
0259, Positioning Velocity
.
When a positioning block is completed, bit 4 (end position reached) is set
in parameter
P-0-4061, Positioning block status word
.
→
|S-0-0430 – S-0-0051/53| < S-0-0057 && no sequential block
The positioning block mode can be interrupted by:
•
removing drive enable
•
activating "Drive Halt"
•
changing the operating mode
•
jogging
•
positioning stop or operational stop (S-0-0346, bit 1 and bit 2 = 1)
•
a drive error occurring
Parameter
P-0-4019, Positioning block mode
is used to define the way
in which the target position is processed in parameter
P-0-4006,
Positioning block target position
. There are the following options:
•
absolute
Positioning
•
relative
positioning
•
relative positioning with residual path storage
•
infinite travel in positive/negative direction
•
sequential block processing
See Parameter Description "P-0-4019, Positioning block mode"
Note:
It is possible to define an individual positioning mode for each
positioning block.
The parameter
S-0-0393, Command value mode
controls the drive
behavior in case "modulo format" was determined as processing format of
the position data.
See also Parameter Description "S-0-0393, Command value
mode"
The following modes are distinguished:
•
shortest
distance
•
positive
direction
•
negative
direction
The following limiting conditions have to be taken into account:
•
If the absolute value of the current actual velocity is greater than the
velocity threshold for positioning in modulo format (S-0-0417), the
drive always moves in the last active direction of rotation.
•
If the target position is within the target position window in modulo
format (S-0-0418), positioning is always carried out according to the
"shortest distance" mode.
Positioning Block Control Word
Position Feedback
Interrupting a Positioning Block
Positioning Block Modes
Command Value Mode
(S-0-0393)
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com