10-64
Handling, Diagnostic and Service Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
General Information on the Oscilloscope Function
Sequence of a Measurement/Status Diagram
DC000011v01_en.FH7
recording stopped
P-0-0028 bit 0: 1
®
0
recording not active
P-0-0029 bit 0 = 0
YES
NO
NO
trigger error
P-0-0029 bit 7 = 1
trigger comparison runs
P-0-0029 bit 1 = 1
NO
internal trigger
P-0-0028 bit 1 = 0
external trigger
P-0-0028 bit 1 = 1
waiting for external signal
P-0-0029 bit 2 = 1
P-0-0037 bit 0 = 1
YES (bit 0 = 1)
NO (bit 0 = 0)
delay function active
P-0-0029 bit 4 = 0
P-0-0037 bit 0 = 1
NO
YES
recording active
P-0-0029 bit 0 = 1
P-0-0029 bit 2,3,7 = 0
setting trigger bits
P-0-0029 bit 2,3 = 1
setting trigger bit
P-0-0029 bit 3 = 1
delay function completed
P-0-0029 bit 4 = 1
recording completely terminated
P-0-0028 bit 0 = 0
internal trigger signal
P-0-0037 bit 0 = 0
YES
YES
start of recording?
P-0-0028 bit 0: 0
®
1
valid trigger signal
available (P-0-0026)?
trigger condition
fulfilled?
kind of trigger?
external trigger signal
available (P-0-0036)?
no. of measured
values reached
(P-0-0033) ?
Fig. 10-27: Status diagram of oscilloscope function