MPH-02, MPB-02, MPD-02
Motor, Mechanical Axis System, Measuring Systems
5-17
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
CAUTION
Property damage caused by movement of non-
equilibrated axes when releasing the holding
brake!
⇒
Before starting the command, move the axis to a
noncritical position!
The control unit can apply the holding brake by means of the following
command when the drive is active:
•
P-0-0543, C2000 Command Apply motor holding brake
CAUTION
Damage to the holding brake!
If the axis is moved with the holding brake
applied, the brake can become prematurely
worn!
⇒
In case of doubt start
P-0-0541, C2100 Brake check
command
!
Displaying the operating status and the monitoring function:
•
P-0-0539, Holding brake status word
Signaling the readiness to accept command values:
•
S-0-0135, Drive status word
•
E2069 Brake torque too low
•
F2069 Error when releasing the motor holding brake
•
F6024 Maximum braking time exceeded
•
C2001 Command not enabled
•
C2101 Brake check only possible with drive enable
•
C2103 Brake torque too low
•
C2104 Command execution impossible
•
C3901 Abrasion of brake only possible with drive enable
•
C3902 Error during abrasion of brake
•
C3903 Command execution impossible
5.2 Rexroth
Motors
Basics on Rexroth Motors
Brief Description
Bosch Rexroth’s "Electric Drives and Controls" technology field offers a
wide range of motors for equipping machines and installations with drives.
With regard to their type of construction the Rexroth electric motors can
be divided into:
•
housing motors with drive shaft and flange or mounting supports
Command "Apply Holding
Brake"
Operating Status
Warnings
Errors
Command Errors