MPH-02, MPB-02, MPD-02
Drive Functions
8-61
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Note:
When actual position reference values are measured, all
machine parts have to have reference temperature!
All temperature data are scaled with the temperature scaling (S-0-0208)
set on the drive side. The factors for linear expansion (P-0-0406,
P-0-0407) are scaled with the quotient position data scaling/temperature
scaling (S-0-0076/S-0-0208).
Position-Independent Temperature Correction
The position-independent temperature correction is used to compensate
the temperature-dependent linear expansion of tools, workpieces and
slides. The expansion of these components of a servo axis only depends
on the temperature difference compared to a reference temperature, the
resulting actual position value error is the same at each position of the
axis.
Pertinent parameters:
•
P-0-0402, Axis correction reference temperature
•
P-0-0405, Axis correction actual temperature pos.-independent
•
P-0-0407, Axis correction temperature factor pos.-independent
Ap5046f2.fh7
servo drive
L
ref. temp
tool
slide
L
ref.temp
:material length the temperature expansion of which has to be
compensated (at reference temperature)
Fig.
8-43:
Example of application for position-independent temperature
correction
Note:
The actual position value system to be corrected is selected
via the respective bit of
P-0-0413, Axis correction control
word
.
Scaling