MPH-02, MPB-02, MPD-02
Motor, Mechanical Axis System, Measuring Systems
5-9
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
released
applied
1
0
(AF internal)
DK000008v01_en.fh7
bit 3: 1
0
S-0-0207
motor
holding
brake
P-0-0115
bit 14: 1
0
bit 15: 1
0
AF from NC
AF reset by NC or error, e.g. with "velocity
command value to zero" error reaction
drive disables NC command values
actual velocity
value
S-0-0273
10 min
-1
or 10 mm/min
t
Fig. 5-3:
Holding brake control with error situation 1 and braking
time < S-0-0273 ("velocity command value reset" error reaction)
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion