The RGC11, Fig. 1, is an IR Remote Controlled Line Level Gain Control Module.  It permits line level gain
control of audio power amplifiers (instead of at speaker level), in multiroom installations, when highest
sound quality is desired.  It may also be used in any application where IR remote control of gain is desired,
such as between the pre-out and main-in jacks of integrated amplifiers or receivers that were built without
remote control.  Gain control is accomplished by way of infrared commands originating from a Xantech
RC68+ (or RC68) Programmer.  The RC68+ commands are "taught" to learning devices and passed to the
RGC11 IR "IN" and "G" terminals via Xantech IR Receivers, Keypads and Connecting Blocks.

LEFT

RIGHT

IR CONFIRM

LEFT

RIGHT

OUTPUT

LOOP

THROUGH

INPUT

RGC11

REMOTE GAIN
CONTROL MODULE

IR

IN    G

15VAC

V    V

Fig. 1 

 The RGC11

INSTALLATION INSTRUCTIONS

RGC11

REMOTE GAIN CONTROL MODULE

FEATURES AND SPECIFICATIONS

• Requires RC68+ (or RC68)  Programmer IR codes or the MIRV1 for operation.

• Responds to 16 IR commands: Volume Up/Down Ramping12 Fixed Levels, Mute ON and Mute OFF.

• IR Confirm LED lights steady when power is applied and blinks off with RGC11 IR commands only.

• Gold plated RCA type input & output jacks.

• Loop-through jacks (not buffered) for "daisy chaining" multiple RGC11’s.

• Selectable IR code groups.  Internal E

2

 PROM can be set to different group codes, allowing different IR

code combinations. This prevents mutual interaction in common IR systems when using more than one
RGC11, or if RGC11's are included with other Xantech products using RC68+ codes.

• Factory preset Group Code number:  30

• 4-terminal plug-in for IR input & power connections, IR IN (= IR Signal)G (= GND)V  V= 15VAC.  Accepts

wire sizes from 24 to 12 gauge.

• Power Requirements:  15VAC @ 85 mA. (15V AC power supply included).

• Gain:  Unity @ Max. V.C.

• Input Impedance:  45 k Ohms

• Output Impedance:  220 Ohms

• Freq. Response: 5 Hz to 70 kHz 

±

 3 dB.

• THD: < 0.01% @ 2V out.

• S/N Ratio: > 103 dB "A" WTD re 2V out.

• Flanges, plus supplied screws, permits easy mounting to flat surfaces..

• Dimensions:  5-7/8" x 2-3/4" x 1-5/8"

Summary of Contents for RGC11

Page 1: ...ECIFICATIONS Requires RC68 or RC68 Programmer IR codes or the MIRV1 for operation Responds to 16 IR commands Volume Up Down Ramping 12 Fixed Levels Mute ON and Mute OFF IR Confirm LED lights steady wh...

Page 2: ...mute commands without knowing what the status is This is very helpful in a remote room when all adjustments are made blind without any visual aids for status NOTE Mute is released turned off with a VO...

Page 3: ...se the Xantech URC 1 or URC 2 learning remote controllers for this purpose NOTE With a Common IR Bus system you cannot carry the same remote control from room to room You must use a dedicated remote f...

Page 4: ...nk IR Receiver 480 00 Smart Pad 3 789 44 Connecting Block ST G V IR IN ST G V IR IN ST G V IR IN L R SOURCE COMPONENTS RGC11 for room 2 RCA Type Patch Cords C H 1 C H 2 BRIDGED STEREO LEVEL LINE INPUT...

Page 5: ...connecting Polarity must be observed as shown in Fig 4 5 For systems using more than five RGC11 s you will need additional 793 00 s These can be easily daisy chained as shown in Fig 5 5 Since a Dedica...

Page 6: ...ST G V IR IN L R SOURCE COMPONENTS RGC11 for room 2 RCA Type Patch Cords C H 1 C H 2 BRIDGED STEREO LEVEL LINE INPUTS 1V 2V 3V Xantech PA640 Input Panel C H 3 C H 4 BRIDGED STEREO LEVEL LINE INPUTS 1...

Page 7: ...e RGC11 is connected between the PRE OUT and MAIN IN jacks on the back of the unit as shown 2 In actual use you would set the unit s front panel volume control to about 50 rotation and use the RGC11 f...

Reviews: