MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-107
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Example:
Write access to the write-protected parameter
S-0-0106, Current loop
proportional gain 1
.
The master tries to write the value "0" to the parameter. The drive
acknowledges with the "0x7004" ("Data cannot be changed") error
message.
Command Telegram:
tel. header
control
byte
device
address
param.
type
parameter no.
(LSB) (MSB)
useful data header
3C
00
04
0B
00
Ta0003f1.fh7
useful data
00
00
Fig. 10-85: Writing the S-0-0106 parameter (command telegram)
Reaction Telegram:
Ta0004f1.fh7
tel. header
status
byte
control
byte
device
address
useful data header
01
3C
00
useful data
04
70
Fig. 10-86: Reading the S-0-0106 parameter (reaction telegram)