96
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Installation and Commissioning
ISDN End Devices
Connecting ISDN End Devices Directly to the Internal U
P0
Port
Connecting ISDN End Devices Directly to the Internal U
P0
Port
Requirements:
•
Inserted COMpact 2BRI module
•
Enabled operating mode “U
P0
internal” on the U
P0
port in question
Note:
The default setting is „S
0
external“ for port 1 and „S
0
internal“ for port 2.
•
Terminators switched on at the internal U
P0
port
•
Short distances between the devices (maximum length of the connection cable used: 10 m)
Note:
If the end device is placed a larger distance away from the PBX, the
cable and the wall sockets must be permanently installed.
•
U
P0
/S
0
adapter
Note:
For connecting one single COMfortel 1100/1200/1400/1500/1600/
2500/2500 AB/2600 system telephone, a U
P0
/S
0
adapter is not necessary.
Depending on the type and number of end devices, proceed as follows.
•
Single COMfortel 1100/1200/1400/1500/1600/2500/2500 AB/2600:
a) Connect the system telephone to the RJ-45 socket on the internal U
P0
port.
•
Another end device or two COMfortel 1100/1200/1400/1500/1600/2500/2500 AB/
2600 units:
a) Insert the U
P0
/S
0
adapter into the RJ-45 socket on the internal U
P0
port.
b) Connect the end devices to the U
P0
/S
0
adapter.
Further steps:
•
To finish commissioning, you need to set up an internal number for the end device in the
configuration manager.