COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
561
Settings
Hardware
Configuring the Use of the external analogue Ports
Requirements:
•
External S
0
port (optional, see chapter Important Information > Product Details > Basic
Assembly and Extensions)
1. Open the page
Hardware > Port configuration
.
2. Select or clear the
S0 bus monitoring
check box.
Configuring the Use of the external analogue Ports
Proceed as follows:
•
Using the configuration manager
Requirements:
•
Selected COMpact 2FXO module
1. Open the page
Hardware > Port configuration
.
2. Under
Use
, select one of the following options:
Note:
If the settings for the module are marked in red, the module is selected but
not inserted.
The numbers under
Port
correspond to the numbers used on the board.
Further steps:
•
If necessary, change the country-specific settings (see chapter Settings > Analogue
Connection > More Information on Country-specific Settings).
free
: Port is not used.
external
: Port is used as external port.