566
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Settings
Identification
Configuring the DSP Module
3. Enter the IPv6 address of the PBX in the
IPv6 address
entry field. Possible entries:
4. Enter the length of the prefix in the
Prefix length
entry field. The prefix specifies to
which subnet the IPv6 address belongs. Possible entries:
5. Enter the address of the IPv6 gateway in the
IPv6 gateway
entry field. Possible
entries:
Configuring the DSP Module
For communication with the DSP module the CPU uses a predefined 8-address subnet in the
IPv4 address space with the network address 192.168.240.24. If the IP addresses contained
therein are already being used within your network for other network devices, you must
configure a different subnet.
Proceed as follows:
•
Using the configuration manager
Requirements:
•
Inserted COMpact 4DSP module
1. Open the page
Administration > IP configuration
.
2. In the
Network address
entry field under
COMpact 4DSP
, enter the network address
of the subnet. Possible entries:
Digits, characters and
:
Digits
1
to
128
Digits, characters and
:
Address with a range of 0 to 255 or 247 (example: 192.168.10.0)