Inter-Integrated Circuit Controller
7-81
MPU Public Peripherals
Stop Condition (STP)
Master mode only.
This bit (1) can be set to a 1 by the local host to generate a stop condition. It
is reset to 0 by the hardware after the stop condition has been generated. The
stop condition is generated when DCOUNT passes 0.
-
0: No action or stop condition detected
-
1: Stop condition queried
Value after reset is low.
Start Condition (STT)
Master mode only.
This bit (0) can be set to a 1 by the local host to generate a start condition. It
is reset to 0 by the hardware after the start condition has been generated. The
start/stop bits can be configured to generate different transfer formats. The
STT and STP can be used to terminate the repeat mode.
-
0: No action or start condition generated
-
1: Start
Value after reset is low.
Table 7–65. STT Settings
STT
STP
Conditions
Bus Activities
1
0
Start
S-A-D
0
1
Stop
P
1
1
Start/stop (COUNT= n)
S-A-D..(n)..D-P
1
0
Start (DCOUNT= n)
S-A-D..(n)..D
DCOUNT is data count value.