Страница 1: ...AR400 Series Router Hardware Reference AR415S AR440S AR441S AR442S AR450S...
Страница 2: ...ithout prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential dama...
Страница 3: ...estart with Default Configuration 13 LEDs and What They Mean 14 AR450S Router 15 Hardware Features 15 Environmental Conditions 16 Power Supply 16 LEDs and What They Mean 16 Asynchronous Interfaces 17...
Страница 4: ...sed around 10BASE T 100BASE TX switch ports The AR440S and AR441S routers include an ADSL port while the AR442S provides an SHDSL port AR415S AR440S AR441S and AR442S routers all include a Port Interf...
Страница 5: ...odems For pin wiring and default communication settings see Asynchronous Interfaces on page 17 one PIC bay Front and rear panels of the AT AR415S router are shown in the following figure Hardware Feat...
Страница 6: ...ports with RJ 45 connectors AT AR027 VoIP FXS PIC two Foreign Exchange Subscriber FXS ports with RJ 11 connectors Environmental Conditions operating temperature range 0 C to 40 C 32 F to 104 F storag...
Страница 7: ...the router is malfunctioning Off Normal operation PIC 0 Green A port interface card PIC is correctly installed and has been detected by the router Off No PIC is installed or the router has not recogn...
Страница 8: ...is wired as a DTE port and can be used as a general purpose port for terminals printers or modems For pin wiring and default communication settings see Asynchronous Interfaces on page 17 one PIC bay F...
Страница 9: ...d operating in V 35 mode synchronous PICs have full V 35 functionality but their output voltages may not be within the voltage range set by the V 35 specification Synchronous PICs installed in an AR44...
Страница 10: ...installed and has been detected by the router Off No PIC is installed or the router has not recognised the PIC 1 5 Green A 100 Mbps link has been established through the corresponding switch port Gre...
Страница 11: ...ASYN0 has a DB9 male connector is wired as a DTE port and can be used as a general purpose port for terminals printers or modems For pin wiring and default communication settings see Asynchronous Int...
Страница 12: ...c rate ISDN S T port AT AR021 U BRI U PIC one basic rate ISDN U port AT AR022 ETH PIC one Ethernet LAN AUI 10BASE T port AT AR023 SYN PIC one synchronous port with universal 50 way AMPLIMITE connector...
Страница 13: ...h Default Configuration To restart the router with the default configuration either press the Reset button on the rear panel or use the command restart router config none This restarts the router imme...
Страница 14: ...een A 100 Mbps link has been established through the switch port Green flashing Data is being transmitted at 100 Mbps Amber A 10 Mbps link has been established Amber flashing Data is being transmitted...
Страница 15: ...nd default communication settings see Asynchronous Interfaces on page 17 The following figure shows the front and rear panels of the AT AR450S router Hardware Features 400 MHz RISC processor 64 MBytes...
Страница 16: ...ter has a universal AC input connector and a power switch on its rear panel The router requires a power input of 100 VAC to 240 VAC and 50 Hz to 60 Hz LEDs and What They Mean The following table shows...
Страница 17: ...em See the Terminal Server chapter of your router s Software Reference for more details A typical terminal connection will only require RXD TXD and GND but refer to the equipment manual for the connec...
Страница 18: ...t the PICs that can be installed in each model Installation information for PICs is in the Port Interface Card Installation and Safety Guide Detailed PIC hardware information is in the Port Interface...
Страница 19: ...h memory size is lower than expected then the router s boot process has not correctly detected or recognised the flash memory s presence If recognition fails contact your authorised Allied Telesis dis...
Страница 20: ...to boot 1 MBytes device type 28F128 devices 1 location built in programming power off block erase time 1000 milliseconds total erase blocks 128 FFS erase blocks 120 Boot erase blocks 8 erase block si...
Страница 21: ...st the wiring diagrams to follow when constructing terminal and modem cables to connect the asyn port on the router to various connector and port combinations To connect this router To this device Tha...
Страница 22: ...use an RJ 45 to DB9 adaptor wired internally as a crossed cable These adaptors are available in both DB9 female and male versions from data cabling suppliers and are supplied with wires terminated on...
Страница 23: ...y as a crossed cable These adaptors are available in both DB25 female and male versions from data cabling suppliers and are supplied with wires terminated on the RJ 45 socket and pins on the free ends...
Страница 24: ...DB9 female null modem cable wired as in the following diagram RJ 45 to router MiniDin to Macintosh 1 1 2 3 4 5 6 7 8 DCD CTS RTS RXD GND TXD GND DTR Not connected Notes 1 Output from switch or router...
Страница 25: ...B9 female connector wired as DCE use a straight through cable wired as in the following diagram Notes 1 Output from router Input to router DB9FDB9M_2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 Cable Pin 9 Pin...
Страница 26: ...nector wired as DCE use a DB9 female to DB25 female null modem cable wired as in the following diagram DB9 Female to router DTE DB25 Female to PC terminal DTE 20 6 2 3 8 7 5 4 22 1 2 3 4 6 5 7 8 9 Not...
Страница 27: ...e a DB9 female to mini DIN 8 cable wired as in the following diagram Notes 1 Output from router Input to router DB9FDB25M 8 3 2 20 7 6 4 5 1 2 3 4 5 6 7 8 9 Cable DB25 Male Pin View Pin 9 Pin 6 Pin 5...
Страница 28: ...not the interface is functioning correctly In order to produce a comprehensive test report most tests performed by the Test Facility require a loopback plug to be inserted in the interface being test...
Страница 29: ...r RJ 45 switch or eth port To test an eth or switch port use a loopback plug as described in the following figure Not connected Not connected Not Twisted Pair TP Loopback Plug RJ45 connector 1 2 3 4 5...
Страница 30: ...ead from or write to for file requests that do not include a directory specification To prevent unauthorised access to private directories enter a path name in the Restrict to directory field AT TFTP...
Страница 31: ...nu The key to successful use of terminal emulation software with the router is to configure the software and router with matching communications parameters The following procedure can be applied to mo...
Страница 32: ...EV G 3 In the Connect using field on the Connect To dialog box select the COM port on the PC used to connect to the router and click the OK button 4 In the COMn Properties dialog box set port paramete...
Страница 33: ...ttings tab and set the Properties dialog box as follows 6 Click ASCII Setup to display the ASCII Setup dialog box and ensure the following options are not selected Echo typed characters locally Append...
Страница 34: ...p To download software onto the router see the Upgrade chapter in the Software Reference All router software patches and configuration settings are stored as files in flash memory Typically the follow...
Страница 35: ...start up sequence keystrokes on page 36 5 Load the required version specified by the INSTALL parameters from the flash file system as the main boot 6 Start the router 7 Execute the boot configuration...
Страница 36: ...345678 A RAM test failed at the given address In the example it was the fifth test run The RAM test repeats until it passes so a number of messages like this may appear This fault means that the memor...
Страница 37: ...from ROM are complete and the specified router software is about to be started It takes a few seconds to decompress the software version FAIL Unexpected exception Offset 40 Addr 0100045e An unexpecte...
Страница 38: ...be tested independently using the Test Facility software Most tests however will also require the use of a loopback plug See Loopback Plugs for Testing Interfaces on page 28 The following examples sh...
Страница 39: ...ble test int portn where n is the switch port number This runs the test for 4 minutes Use the show test command Test Facility chapter Software Reference to observe the test progress AT AR026 PICs The...
Страница 40: ...ing Diagnostics do not perform checks on AT AR026 PICs 1 Connect a terminal to the console port Connect a terminal to the console port port 0 on the router s rear panel and set the terminal communicat...
Страница 41: ...and ON For more information This hardware manual is not intended as a guide to diagnostics Diagnostics are designed to be run by service personnel only For more information contact your authorised Al...
Страница 42: ...ocument set for your router and where applicable its expansion options The CD ROM also includes tools for managing your router The Document Set includes the Installation and Safety Guide for your rout...
Страница 43: ...lick the document title 4 To browse PDF documents use any of the following to page through a document toolbar buttons such as the Next Page button keyboard shortcuts such as arrow keys commands from t...
Страница 44: ......