Description:
Displays the setpoint memory for the motorized potentiometer of the technology controller.
For p2230.0 = 1, the last setpoint that was saved is entered after ON.
Dependency:
Refer to: p2230
Description:
Sets the signal source to increase the setpoint for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2236
Description:
Sets the signal source to reduce the setpoint for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2235
Description:
Sets the maximum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2238
Description:
Sets the minimum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2237
Description:
Sets the starting value for the motorized potentiometer of the technology controller.
For p2230.0 = 0, this setpoint is entered after ON.
Dependency:
Refer to: p2230
r2231
Technology controller motorized potentiometer setpoint memory / Tec_ctrl mop mem
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
[%]
Scaling:
-
Data set:
-
p2235[0...n]
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
CDS, p0170
Min Max Factory
setting
- - 0
p2236[0...n]
BI: Technology controller motorized potentiometer lower setpoint /
Tec_ctrl mop lower
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Data set:
CDS, p0170
Min Max Factory
setting
- - 0
p2237[0...n]
Technology controller motorized potentiometer maximum value / Tec_ctrl mop max
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
100.00 [%]
p2238[0...n]
Technology controller motorized potentiometer minimum value / Tec_ctrl mop min
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
-100.00 [%]
p2240[0...n]
Technology controller motorized potentiometer starting value / Tec_ctrl mop start
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
-200.00 [%]
200.00 [%]
0.00 [%]